• To protect the environment, never dispose of this product or any kind of waste from consumables at
a household waste collection point. Dispose of these items at one of our dealers or at an authorized
collection site.
Points to Confirm with Operators
At the end of installation or a service call, instruct the user about use of the machine. Emphasize the following
points.
• Show operators how to remove jammed paper and troubleshoot other minor problems by following
the procedures described in the operating instructions.
• Point out the parts inside the machine that they should never touch or attempt to remove.
• Confirm that operators know how to store and dispose of consumables.
• Make sure that all operators have access to an operating instruction manual for the machine.
• Confirm that operators have read and understand all the safety instructions described in the operating
instructions.
• Demonstrate how to turn off the power and disconnect the power plug (by pulling the plug, not the
cord) if any of the following events occur: 1) something has spilled into the product, 2) service or
repair of the product is necessary, 3) the product cover has been damaged.
• Caution operators about removing paper fasteners around the machine. They should never allow
paper clips, staples, or any other small metallic objects to fall into the machine.
Safety Instructions for this Machine
1. The installation must be done by trained service technicians.
2. This machine weighs 316 kg. (695 lb.). At least four persons are required to remove the machine
from its pallet and position it for installation.
3. To prevent fire hazards never use flammable solvents around the machine.
4. Never place any object on the machine.
5. If anything falls into the machine, turn off the main power switch on the right side of the machine, then
disconnect the power cord from the power source.
6. Locate the machine on a sturdy flat surface where it will not be exposed to excessive vibration.
7. To avoid fire hazard, confirm that the ventilation ports are not blocked, so air can flow freely.
8. Gas generated by the molten glue can irritate the eyes, throat, and nose. The machine should always
be used in a well ventilated room.
9. To avoid the dangers of fire and electrical shock, make sure that the machine is never exposed to:
• Excessive high temperatures and/or humidity
7
Summary of Contents for D454-17
Page 1: ...Multi Folding Unit FD5000 Machine Code D454 17 January 2009 ...
Page 2: ......
Page 32: ...4 Registration roller transport motor A x 2 1 Replacement and Adjustment 30 1 ...
Page 54: ...4 Bypass exit paper sensor A x 1 1 Replacement and Adjustment 52 1 ...
Page 111: ...Skew Adjustment 109 1 ...
Page 118: ...1 Replacement and Adjustment 116 1 ...
Page 129: ...Junction Gates Paper Path 127 2 ...
Page 148: ...Electrical Components Transport Sensors 2 Details 146 2 ...
Page 149: ...Operation Sensors Electrical Components 147 2 ...
Page 150: ...Motors Solenoids 2 Details 148 2 ...