8. Remove two screws [A].
9. Hold the 3rd stopper unit [A], and then remove it ( x 2).
• The 3rd stopper unit cannot hang the folding unit drawer without the two screws. If you remove
the 1st stopper unit without any support, the 3rd stopper unit can fall and be broken.
3rd Stopper Motor
1. 3rd stopper unit (
*
1. Replacement and Adjustment
54
1