![Ricoh D454-17 Manual Download Page 113](http://html.mh-extra.com/html/ricoh/d454-17/d454-17_manual_1456218113.webp)
Skew Correction Reference Table
L1
L2
L3
S1
S2
S3
FM1
---
F Long
F Long
---
Lower F
Raise F
---
F Short
F Short
---
Raise F
Lower F
FM2
F Long
---
---
Raise F
---
---
F Short
---
---
Lower F
---
---
FM3
F Long
F Long
---
Raise F
Lower F
---
F Short
F Short
---
Lower F
Raise F
---
FM4
F Long
F Long
---
Raise F
Lower F
---
F Short
F Short
---
Lower F
Raise F
---
FM5
F Long
F Long
---
Raise F
Lower F
---
F Short
F Short
---
Lower F
Raise F
---
FM6
F Long
F Long
F Long
Lower F
Lower F
Raise F
F Short
F Short
F Short
Raise F
Raise F
Lower F
Table Key
You must refer to the "Skew Correction Reference Diagrams". The following abbreviations are used in the
table above.
Term
What It Means
F Long
Front measurement of L1, L2, or L3 is longer than Rear..
F Short
Front measurement of L1, L2, or L3 is shorter than Rear..
S1, S2, S3
Refers to Stopper 1, Stopper 2, Stopper. In the diagrams these are annotated as:
¬
,
Á
,
®
respectively.
Raise F
Raise the front end of the stopper fence. For more, see below.
Lower F
Lower the front end of the stopper fence. For more, see below.
Example: FM1 (Z-fold)
Skew Adjustment
111
1
Summary of Contents for D454-17
Page 1: ...Multi Folding Unit FD5000 Machine Code D454 17 January 2009 ...
Page 2: ......
Page 32: ...4 Registration roller transport motor A x 2 1 Replacement and Adjustment 30 1 ...
Page 54: ...4 Bypass exit paper sensor A x 1 1 Replacement and Adjustment 52 1 ...
Page 111: ...Skew Adjustment 109 1 ...
Page 118: ...1 Replacement and Adjustment 116 1 ...
Page 129: ...Junction Gates Paper Path 127 2 ...
Page 148: ...Electrical Components Transport Sensors 2 Details 146 2 ...
Page 149: ...Operation Sensors Electrical Components 147 2 ...
Page 150: ...Motors Solenoids 2 Details 148 2 ...