Mode No.
Function
Settings
3-902
Forced Process
Control
Performs the 1,000-copy process control
cycles forcibly.
V
SG
initial adjustment
→
V
R
detection
→
V
L
detection
→
V
ADS
(pattern)
adjustment
This mode starts after the
!
key is
pressed.
4-001
Exposure Lamp
Voltage
Adjustment †
Adjusts the exposure lamp voltage
(0.5 V per step [Range: 50.0 V to 75.0 V])
50.0 ~ 75.0 V
Default = 63 V
‡
For 115 V machines, the actual applied
voltage = displayed value x 1.1412.
After doing this SP mode, ADS initial
setting (SP4-201) and forced V
L
detection (SP3-105) must also be
done.
See "Replacement and Adjustment -
Copy Quality Adjustments" for how to
adjust.
°4-002
Exposure Lamp
Voltage Display
†
Displays the current exposure lamp
voltage.
(0.5 V per step [Range: 50.0 V to 85.0 V])
50.0 ~ 85.0 V
For 115 V machines, the actual applied
voltage = displayed value x 1.1412.
4-008
Vertical
Magnification
Adjustment †
Adjusts the magnification in the paper
travel direction.
(0.1% per step [Range: –1.6% to +1.6%])
See "Replacement and Adjustment -
Copy Quality Adjustments" for how to
adjust.
0 ~ 32 V
Default = 16 ‡
SERVICE PROGRAM MODE
13 October 1997
50
Summary of Contents for A212
Page 10: ...MEMO A212 A214 Copier 13 October 1997 MACHINE CONFIGURATION 7...
Page 82: ...COPIER ELECTRICAL COMPONENT LAYOUT 2 3 4 5 6 7 8 1 12 11 10 13 9 A212S500 wmf...
Page 84: ...42 43 44 45 46 47 49 50 51 53 56 57 58 64 63 62 61 60 59 48 52 55 54 A212S502 wmf...
Page 85: ...65 66 67 68 69 70 71 72 73 75 74 79 78 77 76 80 83 82 81 A212S503 wmf...