background image

Series 

KNAR/F, KNARP/F, KNAR-D/F, KNARP-D/F,

 

Page 

9

 

 

KNAR-S/F, KNARP-S/F   

ASME

 

 

9520-032-en 

Revision   15 

TM  9549

 

Edition 11/2018 

  Attachments  such  as  actuators,  position  control-

lers,  limit  switches  etc.  must  satisfy  the  relevant 
safety  regulations  as  regards  explosion  protection 
and,  if  required,  be  designed  in  compliance  with 
ATEX. 

  Special  attention  must  be  paid  to  the  appropriate 

safety  and  explosion  protection  notes  in  the  re-
spective operating manuals. 

  Plastic-lined  valves  must  not  be  operated  with 

carbon disulphide.  

 

Safety note for valves, certified to Clean Air Act (TA Luft) 

Certificate  /  Manufacturer  Declaration  Validity  is 
dependent  on  the  operating  instructions  being  read 
and observed.  

  Carry out regular maintenance intervals and check 

the tightness of the screw connections and tighten 
as necessary. 

 

Transport, storage and disposal 

 

It  is  imperative,  for  all  transport  work,  to 
observe  generally  accepted  engineering 
practice  and  the  accident  prevention 
regulations. 

 

 

The  valve  is  supplied  with  flange  caps.  Do 
not remove them until just before installation. 
They protect the plastic surfaces against dirt 
and mechanical damage. 

Handle the goods being transported with care. During 
transport the valve must be protected against impacts 
and collisions. 
Directly  after  receipt  of  the  goods,  the  consignment 
must be checked for completeness and any in-transit 
damage. 
Do not damage paint protection. 
 

5.1  Storage 

If the valve is not installed immediately after delivery, 
it must be put into proper storage. 
It  should  be  stored  in  a  dry,  vibration-free  and  well-
ventilated  room  at  as  constant  a  temperature  as 
possible.  
Elastomers are to be protected against UV light.  
In general, a storage period of 10 years should not be 
exceeded. 
 

 

5.2  Return consignments 

 

Valves  which  have  conveyed  aggressive  or 
toxic media must be well rinsed and cleaned 
before  being returned to the manufacturer's 
works. 

It  is 

imperative

  to  enclose  a 

safety  information 

sheet  /  general  safety  certificate

  on  the  field  of 

application with the return consignment. 
Pre-printed  forms  are  enclosed  with  the  installation 
and operating manual. 
Safety precautions and decontamination methods are 
to be mentioned. 

 

5.3  Disposal  

Parts of the valve may be contaminated with medium 
which  is  detrimental  to  health  and  the  environment 
and therefore cleaning is not sufficient. 

 

 

Risk  of  personal  injury  or  damage  to  the 
environment due to the medium! 

 

  Wear  protective  clothing  when  work  is  performed 

on the valve. 

  Prior to the disposal of the valve: 

  Collect  any  medium,  etc.  which  has  escaped 

and  dispose  of  it  in  accordance  with  the  local 
regulations. 

  Neutralise any medium residues in the valve. 

  Separate  valve  materials  (plastics,  metals,  etc.) 

and  dispose  of  them  in  accordance  with  the  local 
regulations. 

Summary of Contents for KNAR-D/F Series

Page 1: ...n and maintenance Subject to change without notice Reproduction is generally permitted with indication of the source Richter Chemie Technik GmbH 9520 032 en Revision 15 Edition 11 2018 Series KNAR F K...

Page 2: ...valve with actuator 12 9 2 Assembly 12 9 2 1 Packing bellows 12 9 2 2 Ball valve with lever 12 9 2 3 Ball valve with actuator 12 9 3 Conversion from lever to actuator 13 10 Drawings 13 10 1 Legend 13...

Page 3: ...5 KNAR S F KNARP S F Stainless steel 1 4408 CF8M 316 Lining material PFA PTFE F On request antistatic F L highly permeation resistant F P Temperature range See pressure temperature diagram in Section...

Page 4: ...The end of the stem journal or flat pivot point is marked with flow direction flow rate Kvs and Cv lining material As viewed from above closing is in clockwise direction 1 3 Tightening torques All scr...

Page 5: ...id damage to the valve it is imperative to observe the max admissible actuating torque 1 5 Cavitation coefficient z for 75 duty Cv Cv100 0 75 There are at least 3 different V control ball stem units f...

Page 6: ...used in the area of application of ASME the low temperature of ASTM A395 is limited to 20 F 29 C A special material is used for the ball stem unit for operating limits under 14 F to 76 F 10 C to 60 C...

Page 7: ...urs gases and non boiling liquids of group 1 according to the PED and have a corrosion resistant plastic lining Solids can lead to increased wear damage to sealing surfaces or to a reduction in the se...

Page 8: ...ot completely filled with medium e g during evacuation and filling the formation of an explosive atmosphere must be prevented e g by superimposing a layer of nitrogen It is recom mended to wait 1 hour...

Page 9: ...ipt of the goods the consignment must be checked for completeness and any in transit damage Do not damage paint protection 5 1 Storage If the valve is not installed immediately after delivery it must...

Page 10: ...ock washers One pipe screw per flange is underlaid with toothed disks At the customer s request a setscrew M6 with a hex nut and washer will be provided at each flange as an additional grounding conne...

Page 11: ...mechanical damage by using flange caps See also Section 6 1 Make sure that a remote controlled actuator cannot be switched on by accident 8 Malfunctions Flange connection ball valve pipe is leaking R...

Page 12: ...escribed in Section 9 1 1 9 2 Assembly Prior to assembly all parts are to be cleaned and the plastic lined parts checked for damage Insert seat rings 401 in the main body 101 and body end piece 102 As...

Page 13: ...of V control ball stem unit Observe the actuator position in accordance with the actuator operating manual Tighten setscrew 904 4 in the coupling 804 Tighten sleeve nut 512 on the coupling tight Atte...

Page 14: ...KNARP F KNAR D F KNARP D F Page 14 KNAR S F KNARP S F ASME 9520 032 en Revision 15 TM 9549 Edition 11 2018 10 2 Sectional drawing ball valve with lever Holes of the flange and housing screws view dis...

Page 15: ...KNARP F KNAR D F KNARP D F Page 15 KNAR S F KNARP S F ASME 9520 032 en Revision 15 TM 9549 Edition 11 2018 10 3 Sectional drawing ball valve with actuator Holes of the flange and housing screws view d...

Page 16: ...View and section ball valve with lever View Z Section B B 10 5 Sections ball valve with actuator Section A A Section B B Section B B Tighten packing gland follower 503 until spring gland follower 502...

Page 17: ...lever KNAR F x x x x x x x x KNAR S F x x x DN 1 1 2 3 4 6 8 L inch mm 5 12 130 5 91 150 5 0 127 6 5 165 7 0 178 7 99 203 9 01 229 10 51 267 17 99 457 HL inch mm 7 05 179 10 24 260 12 32 313 20 27 515...

Page 18: ...15 80 4 64 118 5 27 134 7 24 184 H2 inch mm 2 32 60 2 32 60 3 15 80 3 94 100 H3 inch mm H4 inch mm L inch mm 5 12 130 5 91 150 5 0 127 6 5 165 7 0 178 7 99 203 9 01 229 10 51 267 17 99 457 L1 inch mm...

Page 19: ......

Page 20: ......

Page 21: ......

Page 22: ......

Page 23: ...The laws are such as the Health and Safety at Work Act ArbSt ttV the Ordinance on Harzadous Substances GefStoffV BIOSTOFFV the procedures for the prevention of accidents as well as regulations to env...

Page 24: ...tamination of the pumps valves and component sent in for repair On the basis of this information for the contractor is it possible to meet the necessary preventive action during the execution of the r...

Page 25: ...ch cleaning method radioactive3 1 if no then forward to D other pollutant 2 Aggregates which are contaminated with microbiological or explosive substances are only accepted with documented evidence of...

Page 26: ...5241 2870 Email RichterShanghai Info idexcorp com Internet www richter ct com Richter Pumps Valves Inc 406 State Street Cedar Falls 50613 IA USA Tel 1 319 268 8038 Fax 1 319 273 8157 Email RichterCed...