background image

INDEX

1.2 Installation
1.2.1 Standard Installation
1.2.2 Dimension Chart
1.2.3 Components of Installation
1.2.4 Installation of Articulated Arm Opener
1.2.5 Emergency Release
1.2.6 W

i-Fi

 Device

 (Sold Seperately)

1.2.7 Photocells 

(Sold Seperately)

1.2.8 Power Supply Connections
2.1 Wiring Connection
2.1.1 Master Motor is installed at right side
2.1.2 Master Motor is installed at left side
3. Get Started
3.1 Step 1: Remote Memorizing
3.1.1 Memorizing

3.

1.2 Remote learning without control board

3.

1.

3 Deleting 

all memory of all remotes

3.

2 Step 2: System Learning

 

3.

3 Gate-moving Logic

3.4 

Checking the Gate Movement

3.5 

LED Indication

3.5.1 Function of the LED Display

3.6 Parameter

 

3.6.1 Parameter Learning
3.6.2 Parameter

3.6.3 Photocell Logic

 

4. Dimension

5

. Technical Features

6

. Maintenance

1
1
1
2
2
3
3
4
4
5
6
7
8
8
8

8
8

9

10

1

0

1

0

1

0

11

1

1

1

1

1

4

1

5

1

6

16

1.1 Warnings

WARNING : 

This user manual is only for qualified technicians who is specialized in installations and automations.

(1) All installations, electrical connections, adjustments and testing must be performed only after

reading and understanding of all instructions carefully.

(2) Before carrying out any installation or maintenance operation, disconnect the electrical power

supply by turning off the magneto thermic switch connected upstream and apply the hazard area

notice required by applicable regulations.

(3) Make sure the existing structure is up to standard in terms of strength and stability.

(4) When necessary, connect the motorized gate to reliable earth system during electricity connection phase.

(5) Installation requires qualified personnel with mechanical and electrical skills.

(6) Keep the automatic controls (remote, push bottom, key selectors…etc) being placed properly

and away from children.

(7) For replace or repair of the motorized system, only original parts must be applied.  Any damage

caused by inadequate parts and methods will not be claimed to motor manufacturer.

(8) Never operate the drive if you have any suspect with what it might be faulty or damage to the system.

(9) The motors are exclusively designed for the gate opening and closing application, any other

usage is deemed inappropriate. The manufacture should not be liable for any damage resulting

from the improper use. Improper usage should void all warranty, and the user accepts sole

responsibility for any risks thereby may accrue.

(10) The system may only be operated in proper working order. Always follow the standard procedures

by following the instructions in this installation and operating manual.

(11) Only command the remote when you have a full view of the gate.

Please keep this installation manual for future reference.

7

.

Technical Support

1

7

Summary of Contents for GTR502

Page 1: ...GTR502 GTR503 ARTICULATED ARM OPENERS 24V DC MOTOR FOR RESIDENTIAL USER MANUAL Software Version PS21068B...

Page 2: ...ly by turning off the magneto thermic switch connected upstream and apply the hazard area notice required by applicable regulations 3 Make sure the existing structure is up to standard in terms of str...

Page 3: ...that the gate moves smoothly and that 1 Hinges are properly positioned and greased 2 No any obstacle in the moving area 3 No frictions between two leaf gates and on the ground while moving 4 Installat...

Page 4: ...surface of the brackets to be installed is smooth vertical and rigid 3 Arrange the cables for power supply cable of the motors make sure power supply cable is connected to motor 4 Motor installation a...

Page 5: ...6 1 Adjust the gate to full opened position and after the position decided fixe with corresponding mechanical stopper 6 2 Adjust the gate to full opened position and after the position decided make t...

Page 6: ...ver and transmitter should be properly aligned 4 Power up the photocells and make sure the LED light on receiver and transmitter are ON Step 1 Step 2 Step 3 Step 4 Detection Method Sensing Range Input...

Page 7: ...2 UP SET SET DOWN RF LEARN RF LEARN LED2 LED4 LED3 11 2 M 2 M 1 M 1 M t a L t a L t i L t i L D N G 4 t m L 3 t m L D N G 2 t m L 1 t m L D N G 2 S 1 S V 5 GND Ph1 Ph2 PhVcc PhVcc y e K S y e K D D N...

Page 8: ...Limit switch ANT GND PC190 PCB1 40121 377 A1 T4 SW3 UP J1 Q17 R113 R112 R111 R110 R108 R107 R106 R105 R104 R103 R102 J5 SW1 RF LEARN RF1 MOV1 K5 K3 K2 K1 J4 J3 J7 J2 F1 DB1 J8 SW4 SET SW5 DOWN NC NO...

Page 9: ...2 K1 J4 J3 J7 J2 F1 DB1 J8 SW4 SET SW5 DOWN NC NO CO NC NO CO CO NO NC CO NO NC NC NO CO LED2 LED3 LED4 M1 Limit1 Limit2 GND M1 Motor1 Power Limit Switch Antenna ANT GND RF J7 NC NO CO CO NO NC CO NO...

Page 10: ...out any new remote learn then the LED will be off The transmitter learning is completed Antenna figure 1 figure 1 RF Learn New Remote Press any desired button UP A B SET DOWN RF LEARN 3 Sec RF LEARN S...

Page 11: ...eck the parameter setting of F1 Dual Single before going into system learning Restore system default setting Press and Hold the UP DOWN button for 5 secs and panel restores back to default setting Not...

Page 12: ...19 19 19 19 19 LED2 LED4 LED3 3 3 5 3 5 1 Function Of The LED Display LED Display Programmable Functions LED Display Programmable Functions When the gate is opening the LED Display show OPN for 2s an...

Page 13: ...Gate Closing Motor Speed for Opening F1 F3 F4 F5 F11 F22 F23 F31 F32 F33 F34 F41 F42 F43 F44 F51 F52 F F5 54 4 Over current Default Limit Switch Hall Sensor 2A 3A 4A Default 5A 2A 3A 4A Default 5A 50...

Page 14: ...peed 40 of full speed Default 50 of full speed 1 The factory setting is F83 Deceleration Point for Opening F91 F92 F93 F94 F9 F95 75 of full distance 80 of full distance 85 of full distance Default 90...

Page 15: ...h for 3 seconds before the gate operates If set OFF the flash light will operate with motor at the same time 2 The factory setting is FG0 1 The factory setting is FH0 1 The factory setting is FI0 1 Th...

Page 16: ...NO met Table FW Over current Sensitivity Setting F Para W1 FW2 FW3 FW4 1 The factory setting Description is FW5 FW5 FW6 FW9 F FW7 W7 FW8 FWA er 0 1 sec 0 3 sec 0 2 sec 0 4 sec 0 6 sec 0 5 sec Default...

Page 17: ...ime Open No effect Reload automatic closing time PH2 Photocell CLOSE Open Open Open No effect Position of Gate When safety devices are activated FE4 Double photocell set up Type of Safety Device FULLY...

Page 18: ...old Separately 433 92MHz 200 transmitters memory Built in PCBA 20o C 50o C 275mm x 195mm x 102mm Conduct the following operations at least every 6 months If you are a high intensity user please shorte...

Page 19: ...551 2233 Richmond Wheel Castor Co declines all responsibility for any consequences resulting from improper use of the product or use which is different from the expected and specified in the present d...

Page 20: ...at safety Durability Solid material apply with lasting usage Silence Worm gear application give silence operation Manual release device with easy use and highly protection Key Release EZ Instal Easy i...

Reviews: