3.2 Step 2: System Learning
Step1:
Press and
hold
SET
& DOWN
button
s
for 3
sec
s
till
the
LED shows “LEA”
. Within 20
sec
s, press the "open-stop-
close-stop" button on the remote or SET button on the
control
board. T
hen the motor runs the system learning
procedure automatically
.
O
nce
the
learning
is
completed
, the LED
will
show “D-G” or “S-G”
.
Note:
Please check the parameter setting of “F
1
”(Dual/Single) before going into system learning.
Restore system default setting
Press and Hold the
UP + DOWN
button
for 5 secs
and panel restores back to default setting
Note:
11... LE
LED
LE
LED
22...
A.
(1)
Dual Gate
Slave Gate Close → (2) Master Gate Close → (3) Master Gate Open →
(4) Slave Gate Open → (5) Slave Gate Close → (6) Master Gate Close
B. Single Mode :
(1) Master Gate Close → (2) Master Gate Open → (3) Master Gate Close
1
2
3
1
2
3
4
5
6
1
2
3
D-G/S-G
LEA
shows "D-G" tells the system learning has be completed for Dual Gate installation
shows "S-G" tells the system learning has be completed for Single Gate installation
Press