J1 Terminal:
Terminal 5:
Common (Ground).
Terminal 6:
Photocell input (Normally Closed). If no photocell
is fitted use jumper between terminals 5 & 6.
Terminal 7:
Extra power input +24VDC.
J7 Terminal:
Terminal 1:
Optional External Open Push Button Switch.
(Hard Wired keypad connection between terminals 1 & 4)
Terminal 2:
Optional External Close Push Button Switch.
Terminal 3:
Optional External Stop Push Button Switch.
Terminal 4:
Common Terminal for All Optional Push Buttons.
J10 Terminal:
Limit Switch Wiring
OP:
Open Circuit.
COM:
Limit Switch Common Terminal.
CL:
Closed Circuit.
Using a screwdriver, loosen the screw
on the side of the terminal.
insert the wire into
the terminal
Tighten with a screwdriver to secure the
wire in place.
How to secure a wire to the circuit board terminals
Ensure that power is off before completing any wiring