Thank you for choosing this sliding gate opener. Please read the manual carefully before assembling and using 

 

the opener. Do not leave out the manual if you send this product to a third party. This product complies with the 

 

recognised technical standards and safety regulations. Our company has the right to change this manual without 

 

prior notice.

General Safety:

Warning: Incorrect or improper use of this product can cause damage to persons, 

 

animals or properties.

•  Please ensure that the input voltage to the low voltage power supply used matches with the supply voltage of 

gate opener (AC240V 50Hz). 

•  To avoid damaging gas, power or other underground utility lines, contact the relevant authority BEFORE 

digging.

•  All potential hazards and exposed pinch points of the gate must be eliminated or guarded prior to installation 

of this gate motor.

•  Never mount any device that operates the gate motor where the user can reach over, under, around or 

through the gate to operate the controls. These must be placed at least 1.8m from any moving part of the 

moving gate.

•  Ensure power plug is disconnected from the power socket during installation or maintenance. 
•  Keep remote control and other control devices out of children’s reach, in order to avoid unintentional 

activation.

•  Never allow anyone to hang onto the gate while moving.
• 

Please ensure a warning sign provided is fitted to the gate.

•  If required, install infrared photocells (sold separately) to detect obstructions and prevent injury or damage.
•  Instruct all users about the control systems provided and the manual opening operation in case of 

emergency.

•  Ensure that the power cable is connected to a RCD protected power outlet that has been installed by a 

qualified electrician.

• 

Do not install the product in an explosive atmosphere or where there is any danger of flooding.

• 

This product was exclusively designed and manufactured for the use specified in the present documentation. 

Any other use not specified in this documentation could damage the product and be dangerous.

•  Only use original parts for any maintenance or repair operation. Richmond Wheel & Castor Co declines all 

responsibility with respect to the automation safety and correct operation when other supplier’s components 

are used.

•  Do not modify the automation components, unless explicitly authorised by Richmond Wheel & Castor Co.
•  The user must avoid any attempt to carry out any works or repairs on the motor, and should always request 

the assistance of qualified personnel.

•  This motor is suitable for use on one sliding gate only.
•  Anything which is not expressly provided for in these instructions is not allowed and will void warranty.
•  Dispose of all packing materials (plastic, cardboard, polystyrene etc.) according to current guidelines.  

Keep plastic bags and polystyrene out of children’s reach.

Please save these instructions for future use.

Summary of Contents for GTR207

Page 1: ...nal 613 9551 2233 For installation or troubleshooting assistance visit richmondau com gate motor support When mounting and positioning the motor ensure that the power cable is unplugged The motor cove...

Page 2: ...he gate at the push of a button Hard Wire Push Button GTR202 Allows access through the gate at the push of a button Reflective Photocells GTR208 Increase safety during opening closing by preventing ga...

Page 3: ...6 Fitting the Mounting Plate Motor 13 Step 7 Gear Rack Motor Alignment 14 Step 8 Limit Travel Stops 16 Step 9 Powering the Motor 18 Step 10 Testing the Limit Travel Stops 19 Programming and Wiring Con...

Page 4: ...on This will give you an understanding of the way in which the motor will move the gate If your gate needs to open from the other direction to the left refer to fig 2 your motor needs to be mounted on...

Page 5: ...hile moving Please ensure a warning sign provided is fitted to the gate If required install infrared photocells sold separately to detect obstructions and prevent injury or damage Instruct all users a...

Page 6: ...11 for more info 1 4 Manual release keys These keys are needed during power outage keep on hand 2 5 Remote controls factory paired to motor 2 6 Gate Warning Signage must be fitted to gate 1 7 In the...

Page 7: ...16 18m min Maximum weight of gate 800 Kg Remote control distance Up to 30m Remote control mode Single button mode Limit switch Spring limit switch Noise Up to 58dB Working duty S2 20min 20 minutes co...

Page 8: ...re mounted outdoors a RCD Protected Weatherproof PowerPoint will be required This will require a licensed electrician to install Any works done to the motor must be completed whilst the power is off a...

Page 9: ...evel 12mm Masonry Drill Bit for the 4 motor masonry anchor bolts Socket and Spanner Set Phillips Head Screwdriver Example Sliding Gate Setup If you require any gate hardware contact Richmond Wheel Cas...

Page 10: ...els and guide rollers should rotate easily and be free from dirt grime Track should be flat level and firmly affixed Any misalignment in the gate will affect performance of the automatic gate opener T...

Page 11: ...able when installing the power supply Option 1 Run the cable across the yard property and bury it Option 2 Run the cable along the fence line of the property and secure out of the way For added protec...

Page 12: ...ode and check that the motor cog rotates freely by hand As per Fig 23 Place the motor and motor mounting plate on the concrete pad Make sure the distance between the gate motor cog and gear rack posit...

Page 13: ...plate ensuring the power cord is positioned into the end slot of the mounting plate in the direction of the power point making sure there are no pinch points as per fig 17 Slide rubber grommet along t...

Page 14: ...rry any weight of the gate It is the task of the gate castors or wheels to carry the weight of the gate As per Fig 22 If the gate doesn t slide freely by hand adjust gear racks height accordingly unti...

Page 15: ...GTR207 Installation Manual Rev 1b 15 Fig 24 At this stage of final assembly the cover is removed not shown and the power cable is still unplugged...

Page 16: ...n setting new limit travel stop positions please ensure that you turn the power off and then on again Turning the power off will reset the limit travel stop memory allowing for new limit travel stop p...

Page 17: ...7 Installation Manual Rev 1b 17 Fig 28 Fig 29 M6 x 10mm M6 x 10mm GTR207 Motor Gear Rack Limit Travel Stop Motor Gear Cog Spring Limit Switch Mounting Plate This diagram shows the gate in the open pos...

Page 18: ...Part 5 included in this kit are factory paired ready for use Please Note The default setting is opening to the right Press the remote control and the gate will open until the spring limit travel stop...

Page 19: ...osed final position for the gate frame is 10 15mm from closed gate end catch GTR019 Testing the open position Press remote The gate will begin to open The limit travel stop will hit the spring limit s...

Page 20: ...ram 01 Ensure power is off before any modifications are made Dip Switches J10 Terminal J8 Terminal J4 Terminal J2 Terminal 24VDC BAT Terminal J7 Terminal Fuse holder J1 Terminal Learn Button Potentiom...

Page 21: ...efore any modifications are made Learn Button Storage Battery 24VAC 24VAC Motor 24VDC Infrared Sensor COM COM COM CLOSED OPEN Stop Button Close Button Open Button Warning Lamp M Please refer to page 2...

Page 22: ...made 30m Direct Bury Cable J2 Terminal Please note 24VAC power has no postitive or negative so either wire from the low voltage power supply can be secured in either of the positions in the J2 POWER t...

Page 23: ...is OFF External Button Mode Leave in OFF position unless an additional module is used Default position is OFF 4 OFF Hard wire keypad Left Right Open Setting OFF Right hand open ON Left hand open Gate...

Page 24: ...to decrease The default setting is at maximum When stall force is enabled DIP switch 7 is at the ON position the motor will detect obstacles and impacts to the gate If this is during opening the gate...

Page 25: ...4 Terminal 2 Optional External Close Push Button Switch Terminal 3 Optional External Stop Push Button Switch Terminal 4 Common Terminal for All Optional Push Buttons J10 Terminal Limit Switch Wiring O...

Page 26: ...Fitted pre wired Circuit board connection for low voltage power supply J4 MOT Terminal Factory Fitted pre wired DC motor wire connection Red wire to top black wire to bottom BAT Terminal Battery Backu...

Page 27: ...will depend on the size and setup of your gate position of the panels and geographical area Under normal conditions we recommend 2 x 12V 12Ah batteries and 1 24V 30W solar panel Note that performance...

Page 28: ...tion the gate should be checked every 6 months Check and tighten anchor bolts Check for loose and corroded wires Ensure your gate can still move smoothly by hand by placing the gate into manual mode u...

Page 29: ...e sure photocell beams are correctly positioned Gate does not move when button is pressed but motor makes a noise 1 Gate is out of alignment 1 Connect in manual mode and check if it can be opened by h...

Page 30: ...or assistance with installing your gate motor visit richmondau com gate motor support Or ring your local Richmond Wheel Castor Branch AU 1300 474 246 NZ 0800 61 71 81 International 613 9551 2233 Richm...

Page 31: ...GTR207 Installation Manual Rev 1b 31 Additional Drawings and Measurements 230mm 270mm 300mm Fig 36...