21
Revision 28
Dip Switch Adjustment:
All changes to these settings must be completed by a licensed electrician
Number Description
Soft Start/Close Function
OFF
– enabled
ON
– disabled
Default position is OFF
(Do not disable)
Limit Switch Setting
OFF
– Normal Open
ON
– Normal Close
Default position is ON,
this should not be changed.
Remote Control Close Function
3 OFF 4 OFF: Factory default setting:
The gate is operated by remote control operation only and will not close
automatically. The gate will remain open until closed again with a remote.
Optional Automatic Close Function
Richmond strongly recommends that you install infrared photocells if using
the motor in auto close mode.
3 OFF 4 ON: automatic close delay time is 12s.
3 ON 4 OFF: automatic close delay time is 24s.
3 ON 4 ON: automatic close delay time is 36s.
3 ON 4 OFF: Hard wire keypad. Automatic close function.
Stall Force Mode (When in default position, detects obstacles, stops
gate, and reverses. To adjust, refer to VR1: Stall Force Mode)
Default position is OFF (enabled)
this should not be changed.
If the switch is set to ON, stall force mode will be disabled
Right-Hand to Left-Hand Opening Switch
Default position is OFF. This is set for a gate that OPENS to the Right
→→
Set the switch to ON for a gate that OPENS to the Left