Dip Switch Adjustment:
All changes to these settings must be completed by a licensed electrician
Number
Description
Automatic Close Function
1 ON 2 OFF: automatic close delay time is 3s.
1 OFF 2 ON: automatic close delay time is 10s.
1 ON 2 ON: automatic close delay time is 30s.
1 OFF 2 OFF: no automatic close function.
Default position is 1 OFF 2 OFF
Remote Control Mode
leave in OFF position unless an additional module is used.
Default position is OFF
External Button Mode
Leave in OFF position unless an additional module is used.
Default position is OFF
4 OFF: Hard wire keypad
Left/Right Open Setting
OFF
– Right hand open
ON
– Left hand open
Gate close direction will be changed after motor is restarted
Default position is OFF (right hand)
Swap over CL & OP limit switch lines on terminal J10 (refer to page 24)
Magnetic Limit Switch
Leave in the ON position,
OFF - Normal close
ON - Normal open
Default position is ON
Magnetic limit switch, Normally Open/Normally Closed, usually the magnetic
limit switch is Normally Open.
Stall Force
ON - Enabled
OFF - Disabled
Default position is ON
Infrared Detection Delay When Closing
ON
– Infrared detection delay is set to 1 second
OFF
– Infrared detection delay is disabled
Default position is OFF