background image

Rev 20A

 

 

Thank you for choosing this sliding gate opener. Please read the manual carefully before assembling and 

using it. Do not leave out the manual if you send this product to a third party. This product complies with 

the recognised technical standards and safety regulations. Our company has the right to change this 

manual without prior notice.

 

 

General Safety: 

Warning

: Incorrect or improper use of this product can cause damage to persons, animals or 

properties. 

 

Please ensure that the input voltage used matches with the supply voltage of gate opener (AC240V 
50Hz).  

 

All modifications to wiring or electrics, and any adjustment or maintenance to 240VAC 

MUST

 be done 

by a qualified electrician. 

 

To avoid damaging gas, power or other underground utility lines, contact the relevant authority 
BEFORE digging. 

 

All potential hazards and exposed pinch points of the gate must be eliminated or guarded prior to 
installation of this gate motor. 

 

Never mount any device that operates the gate motor where the user can reach over, under, around or 
through the gate to operate the controls. These must be placed at least 1.8m from any moving part of 
the moving gate. 

 

Ensure power plug is disconnected from the power socket during installation or maintenance.  

 

Keep remote control and other control devices ou

t of children’s reach, in order to avoid unintentional 

activation. 

 

Never allow anyone to hang onto the gate while moving. 

 

Please ensure a warning sign provided is fitted to the structure. 

 

To ensure safety, before installing the main motor, mount a Gate End Stop (GTR017) and a Gate Stopper 
(GTR017 or GTR018) at each end of the rail to prevent the gate travelling off the track. 

 

If required, install infrared photocells (GTR096, sold separately) to detect obstructions and prevent 
injury or damage. 

 

Instruct all users about the control systems provided and the manual opening operation in case of 
emergency. 

 

Ensure that the power cable is connected to a RCD protected weatherproof power outlet installed by a 
qualified electrician. 

 

Do not install the product in an explosive atmosphere or where there is any danger of flooding. 

 

This product was exclusively designed and manufactured for the use specified in the present 
documentation. Any other use not specified in this documentation could damage the product and be 
dangerous. 

 

Only use original parts for any maintenance or repair operation. Richmond Wheel & Castor Co declines 
all responsibility with respect to the automation safety and correct operation when other supplier’s 
components are used. 

 

Do not modify the automation components, unless explicitly authorised by Richmond Wheel & Castor 
Co. 

 

The user must avoid any attempt to carry out any works or repairs on the motor, and should always 
request the assistance of qualified personnel. 

 

This motor is suitable for use on one sliding gate only. 

 

Anything which is not expressly provided for in these instructions is not allowed and will void warranty. 

 

Dispose of all packing materials (plastic, cardboard, polystyrene etc.) according to current guidelines. 
Keep plastic bags and poly

styrene out of children’s reach. 

 
 
Please save these instructions for future use. 

 
 
 
 
 

Summary of Contents for GTR064

Page 1: ...eel Castor Co on 1300 474 246 When mounting and positioning the motor ensure that the power cable is unplugged The motor cover will need to be removed to mount the motor to the mounting plate Any chan...

Page 2: ...ough the gate used with a user set code Hard Wire Keypad GTR199 Allows secure access through the gate used with a user set code Warning Light GTR198 Alerts people near the gate and users that the gate...

Page 3: ...Step 7 Limit Travel Stops 15 Step 8 Powering the Motor 17 Step 9 Testing the Limit Travel Stops 18 Programming and Wiring Control Board Diagrams 19 Dip Switch Adjustment 20 Further Settings and Progra...

Page 4: ...ay from the motor cog whilst it is turning If your gate needs to open from the other direction to the left refer to fig 2 your motor needs to be mounted on the left hand side as shown a licensed elect...

Page 5: ...tructure To ensure safety before installing the main motor mount a Gate End Stop GTR017 and a Gate Stopper GTR017 or GTR018 at each end of the rail to prevent the gate travelling off the track If requ...

Page 6: ...Warning Signage must be fitted to gate 1 6 In the accessories box you will find the items below 1 6a Magnetic limit travel stops and mounting brackets one for opening and one for closing 1 small brack...

Page 7: ...ight of gate 1000 Kg Remote control distance Up to 30m Remote control mode Single button mode Limit switch Magnetic limit switch Noise Up to 58dB Working duty S2 20min 20 minutes continuous operation...

Page 8: ...wands and warning light Power Supply The GTR064 requires 1 x 10Amp AC240V 50Hz power supply RCD Protected Weatherproof PowerPoint The GTR064 comes complete with a power lead and plug that is 1m long I...

Page 9: ...onry Drill Bit for the 4 motor masonry anchor bolts Socket and Spanner Set Phillips Head Screwdriver Example Sliding Gate Setup If you require any gate hardware contact Richmond Wheel Castor Co or an...

Page 10: ...Gate Opener Wheels and guide rollers should rotate easily and be free from dirt grime Track should be flat level and firmly affixed Any misalignment in the gate will affect performance of the automati...

Page 11: ...four corners of the mounting plate on the concrete pad using a pencil chalk or similar to ensure the mounting plate is in the correct position before drilling Remove motor from the mounting plate Ste...

Page 12: ...er fig 9 Slide rubber grommet along the power lead and into the end slot of the mounting plate as per figures 10 11 Bolt motor to the mounting plate using the M8 x 50mm bolts with spring and flat wash...

Page 13: ...ld the gate motor drive cog carry any weight of the gate It is the task of the gate castors or wheels to carry the weight of the gate As per Fig 14 If the gate doesn t slide freely by hand adjust gear...

Page 14: ...14 Rev 20A Fig 16 Please Note The warning signage provided Part 5 must be displayed on the frame of your automatic gate at all times Fig 17...

Page 15: ...s Closed Position Position gate 150 200mm back from the gate end catch closed position This will help in making sure you do not slam the gate into the gate end catch Position Magnetic Limit Travel Sto...

Page 16: ...GER should be positioned at the closed position Magnetic Limit Travel Stop A SMALLER should be positioned at the open position A B Fig 21 Fig 22 Fig 23 Fig 24 Fig 25 If the limit travel stops are more...

Page 17: ...rproof outlet Remote controls Part 4 included in this kit are factory paired ready for use Note The default setting is opening to the right Press the remote control and the gate will open until the ma...

Page 18: ...l position for the gate frame is 10 15mm from the closed gate end catch GTR019 Testing the open position Press remote The gate will begin to open The gate will stop when the magnetic limit travel stop...

Page 19: ...19 Rev 20A Programming and Wiring Control board wiring diagram 01 Any works to the 240V AC must only be performed by a licensed electrician Ensure power is off before any modifications are made Fig 27...

Page 20: ...20 Rev 20A Programming and Wiring Control board wiring diagram 02 Fig 28 Please refer to page 24 25 for added description of terminals...

Page 21: ...Input Connection WARNING Do not touch 240VAC All works to mains power must be conducted by a licensed electrician Fig 29 Live parts behind cover DO NOT TOUCH All works to mains power must be conducte...

Page 22: ...dditional module is used Default position is OFF 4 OFF Hard wire keypad Left Right Open Setting OFF Right hand open ON Left hand open Gate close direction will be changed after motor is restarted Defa...

Page 23: ...ase counter clockwise to decrease The default setting is at maximum When stall force is enabled DIP switch 7 is at the ON position the motor will detect obstacles and impacts to the gate If this is du...

Page 24: ...Push Button Switch Terminal 3 Optional External Stop Push Button Switch Terminal 4 Common Terminal for All Optional Push Buttons J10 Terminal Factory Fitted pre wired CL Close Magnetic Limit Switch C...

Page 25: ...d electrician J2 Terminal Factory Fitted pre wired Connect to 24VAC power from transformer BAT Terminal Battery Backup Terminal J4 Terminal Factory Fitted pre wired DC motor wire connection Red wire t...

Page 26: ...am of the photocell is blocked the gate will stop and reverse immediately to protect user and property security To install photocells connect wiring as per Figure 30 You must remove the wire jumper be...

Page 27: ...lar power and battery will depend on the size and setup of your gate position of the panels and geographical area Under normal conditions we recommend 2 x 12V 12Ah batteries and 1 24V 30W solar panel...

Page 28: ...28 Rev 20A Solar Panel Connection Solar panel Solar charge Controller Control board POWER Storage battery LED LED LED CHARGE LOAD BATTERY Fig 28 Battery Part Number GTR160...

Page 29: ...ighten anchor bolts Check for loose and corroded wires Check the earth wire green yellow is firmly attached to the housing with the screw This should be checked by a licensed electrician Always check...

Page 30: ...he J1 terminal and dip switch 6 is set to ON If photocell is connected remove jumper 5 and 6 and ensure the wiring is correct and dip switch 6 is set to OFF N C 4 Make sure photocell beams are correct...

Page 31: ...l Support For support or assistance with installing your gate motor ring your local Richmond Wheel Castor Branch on 1300 474 246 For detailed technical support ring our Engineering Department on 03 95...

Page 32: ...32 Rev 20A Additional Drawings and Measurements Magnetic Limit Switch Sensor located beneath the motor cover...

Reviews: