background image

GTR057 Installation Manual: 

Rev 2

 

8

 

 

 

8. Additional Functions 

The Zone 2, it can be used to operate the doorbell 
when there is no need to operate a second door. The 
wiring is connecting the doorbell NO2 and COM2. 
Press #, the reader will send out a switching signal to 
the doorbell, as long as you press the “#”, the door 
bell will continuously operate, it will stop until you 
release the “#” 

 

9. Relay Operation (Pulse mode and 
Toggle mode) 

The two on board relays can operate in either Pulse 
Mode (suitable for access control) or Toggle Mode 
(suitable for arming/disarming alarms, switching lights, 
machines…etc) 

Every time a valid card/tag read or valid PIN input in 
Pulse Mode, the relay will operate, for the pre-set 
relay pulse time. 

Every time a valid card/tag read or valid PIN input in 
Toggle Mode, the relay changes state, which will not 
turn back until read card or input PIN again. 

 

10. Reset to Factory Default

 

To reset to the factory default, power off, press  

hold it and power on, release it until you hear three 
beeps (two short, one long). This means you have 
successfully reset to the factory default. 

Please Note: If you reset to factory default the user’s 
information is still retained 

 

 11. Anti-Tamper Alarm 

The GTR057 uses a LDR (light dependent resistor) as 
an anti-tamper alarm. If the keypad is removed from 
the cover then an alarm will operate. 

 

 

 

 

 

Sound and Light Indication 

Operation Status 

Red Light 

Green Light 

Blue Light 

Buzzer 

Zone1 unlock 

Bright 

Short Ring 

Zone2 unlock 

Bright 

Short Ring 

Power on 

Bright 

Long Ring 

Stand by 

Shines slowly 

Press keypad 

Short Ring 

Operation successful 

Bright 

Long Ring 

Operation failed 

3 Short Rings 

Enter programming mode 

Bright 

Long Ring 

In the programming mode 

Bright 

Bright 

Exit programming mode 

Shines slowly 

Long Ring 

Alarm 

Shines slowly 

Alarm 

 

 

 

Summary of Contents for GTR057

Page 1: ...GTR057 Installation Manual Rev 2 1 Metal Waterproof Access Keypad GTR057 Suits the Following Richmond Gate Motors GTR064 GTR207 GTR061 GTR156 GTR212 GTR099 GTR058...

Page 2: ...to 1100 PIN Card holders Zone 2 up to 100 PIN Card holders PIN Length 4 6 digits Card type 125KHz EM card Can be used as a standalone keypad Pulse mode Toggle Mode Block enrolment can enrol 1100 conse...

Page 3: ...1 User ID Number PIN For Zone 2 1 User ID Number PIN The ID number is any number between 1 1100 for Zone 1 and any number between 1101 1200 for Zone 2 Users can be added continuously without exiting p...

Page 4: ...Installation Manual Rev 2 4 How to connect to the GTR156 GTR212 control board The below diagram shows how to connect the wires from the GTR057 wired keypad to the GTR156 GTR212 Automatic Slide Gate O...

Page 5: ...lation Manual Rev 2 5 How to connect to the GTR061 GTR064 GTR207 control board The below diagram shows how to connect the wires from the GTR057 wired keypad to the GTR061 GTR064 GTR207 Automatic Slide...

Page 6: ...GTR057 Installation Manual Rev 2 6 How to connect to the GTR099 control board The below diagram shows how to connect the wires from the GTR057 wired keypad to the GTR099 Automatic Swing Gate Opener...

Page 7: ...GTR057 Installation Manual Rev 2 7 How to connect to the GTR058 control board The below diagram shows how to connect the wires from the GTR057 wired keypad to the GTR058 Automatic Swing Gate Opener...

Page 8: ...relay changes state which will not turn back until read card or input PIN again 10 Reset to Factory Default To reset to the factory default power off press hold it and power on release it until you he...

Page 9: ...the working mode Card PIN or Card PIN Set valid Card or PIN users 3 1 2 Zone 1 3 2 2 Zone 2 Entry is by either Card or PIN Factory default setting Set valid Card and PIN users 3 1 1 Zone 1 3 2 1 Zone...

Page 10: ...cards users Block Enrolment The card numbers must be consecutive This operation is only for Zone 1 5 User ID number 8 digits Card number Card quantity Card quantity is between 1 1100 of the 8 digits c...

Page 11: ...d 2 Note This is done outside of programming mode so a user can undertake this themselves User ID number Old PIN New PIN New PIN To delete a Card and PIN user just delete the card 2 Read card or 2 Use...

Page 12: ...ically Door Forced Open warning When used with and optional magnetic contact or built in magnetic contact of the lock if the door is forced open or if the door is opened after 120 seconds of the elect...

Page 13: ...to operate the doorbell The wiring is connecting the doorbell to COM2 and NO2 Press the keypad will send the signal to the doorbell Zone 2 8 8 Factory default Doorbell 8 9 Remove the alarm To remove t...

Reviews: