GTR057 Installation Manual:
Rev 2
10
Adding Users
To add a PIN user(s)
1 User ID number # PIN #
The ID number is any number among 1-1100. The PIN is
any 4-6 digits between 0000
– 999999 except for 1234
which is reserved. Users can be added continuously without
exiting programming mode as follows:
1 User ID number1 # PIN # User ID number2 # PIN #
To delete a PIN user
2 User ID number #
Users can be deleted continuously without exiting
programming mode.
To change the PIN of a PIN user
(Note: This step must be done out of
programming mode)
✱
User ID number #
Old PIN # New PIN # New PIN #
To add a card user (Method 1)
This is an easy way to enter cards with
auto-generated ID numbers. The ID number will
start from 1 if no user has been programmed.
1 Read Card #
Cards can be added continuously without exiting
programming mode.
To add a card user (Method 2)
1 User ID number # Card #
The ID number can be any number between 1-1100
To add a series of cards users
(Block Enrolment).
The card numbers must be consecutive
(This operation is only for Zone 1)
5 User ID number # 8 digits Card number # Card quantity #
Card quantity is between 1-1100 of the 8 digits card
number, it is the last 8 digits on the card (Maximum 1100
cards can be enrolled at a stretch within 1 minute).
To delete card users by cards
Note: Users can be deleted continuously
without exiting programming mode
2 Read Card #
The device can automatically identify the card of Zone 1 or
Zone 2
To delete card users by user ID
This can be used if a user has lost their card
2 User ID #
To delete card users by card number
9 Input 8 digits card number #
Cards can be deleted continuously without exiting from
programming mode.
To set user for Zone 2 ( 3 2 2 # )
To set
PIN user
for Zone 2 is the same as Zone 1, only the ID number is 1101
– 1200 for Zone 2.
To set
Card user
for Zone 2 is the same as Zone 1, with the exception of adding card users with auto-
generated ID numbers (Method 1) as below.
To add card users (Method 1)
Auto-generated ID numbers
5 Read Card #
Card can be added continuously without exiting
programming mode.