Adding Users

 

To add a PIN user(s) 

1  User ID number  #  PIN  # 
 
The ID number is any number among 1-1100. The PIN is 
any 4-6 digits between 0000 

– 999999 except for 1234 

which is reserved. Users can be added continuously without 
exiting programming mode as follows: 
 
1 User ID number1 #  PIN  #  User ID number2 #  PIN #  

To delete a PIN user 

2  User ID number  # 

 

Users can be deleted continuously without exiting 
programming mode. 

To change the PIN of a PIN user  
(Note: This step must be done out of 
programming mode) 

  User ID number #

  

Old PIN #   New PIN #   New PIN # 

To add a card user (Method 1) 
This is an easy way to enter cards with  
auto-generated ID numbers. The ID number will 
start from 1 if no user has been programmed. 

1  Read Card  # 

 

Cards can be added continuously without exiting 
programming mode. 

To add a card user (Method 2) 

1  User ID number  #  Card  # 

 

The ID number can be any number between 1-1100 

To add a series of cards users  
(Block Enrolment).  
 
The card numbers must be consecutive  
(This operation is only for Zone 1) 

5 User ID number # 8 digits Card number # Card quantity # 

 

Card quantity is between 1-1100 of the 8 digits card 
number, it is the last 8 digits on the card (Maximum 1100 
cards can be enrolled at a stretch within 1 minute). 

To delete card users by cards 

 

Note: Users can be deleted continuously 
without exiting programming mode 

2  Read Card  # 

 

The device can automatically identify the card of Zone 1 or 
Zone 2 

To delete card users by user ID 
This can be used if a user has lost their card 

2  User ID  # 

To delete card users by card number 

9  Input 8 digits card number  # 

 

Cards can be deleted continuously without exiting from 
programming mode. 

To set user for Zone 2 ( 3  2  2  # ) 

To set 

PIN user

 for Zone 2 is the same as Zone 1, only the ID number is 1101 

– 1200 for Zone 2. 

To set 

Card user

 for Zone 2 is the same as Zone 1, with the exception of adding card users with auto-

generated ID numbers (Method 1) as below. 

To add card users (Method 1)  
Auto-generated ID numbers 

5  Read Card  # 
 
Card can be added continuously without exiting 
programming mode. 

Summary of Contents for GTR057

Page 1: ...GTR057 Installation Manual Rev 2 1 Metal Waterproof Access Keypad GTR057 Suits the Following Richmond Gate Motors GTR064 GTR207 GTR061 GTR156 GTR212 GTR099 GTR058...

Page 2: ...to 1100 PIN Card holders Zone 2 up to 100 PIN Card holders PIN Length 4 6 digits Card type 125KHz EM card Can be used as a standalone keypad Pulse mode Toggle Mode Block enrolment can enrol 1100 conse...

Page 3: ...1 User ID Number PIN For Zone 2 1 User ID Number PIN The ID number is any number between 1 1100 for Zone 1 and any number between 1101 1200 for Zone 2 Users can be added continuously without exiting p...

Page 4: ...Installation Manual Rev 2 4 How to connect to the GTR156 GTR212 control board The below diagram shows how to connect the wires from the GTR057 wired keypad to the GTR156 GTR212 Automatic Slide Gate O...

Page 5: ...lation Manual Rev 2 5 How to connect to the GTR061 GTR064 GTR207 control board The below diagram shows how to connect the wires from the GTR057 wired keypad to the GTR061 GTR064 GTR207 Automatic Slide...

Page 6: ...GTR057 Installation Manual Rev 2 6 How to connect to the GTR099 control board The below diagram shows how to connect the wires from the GTR057 wired keypad to the GTR099 Automatic Swing Gate Opener...

Page 7: ...GTR057 Installation Manual Rev 2 7 How to connect to the GTR058 control board The below diagram shows how to connect the wires from the GTR057 wired keypad to the GTR058 Automatic Swing Gate Opener...

Page 8: ...relay changes state which will not turn back until read card or input PIN again 10 Reset to Factory Default To reset to the factory default power off press hold it and power on release it until you he...

Page 9: ...the working mode Card PIN or Card PIN Set valid Card or PIN users 3 1 2 Zone 1 3 2 2 Zone 2 Entry is by either Card or PIN Factory default setting Set valid Card and PIN users 3 1 1 Zone 1 3 2 1 Zone...

Page 10: ...cards users Block Enrolment The card numbers must be consecutive This operation is only for Zone 1 5 User ID number 8 digits Card number Card quantity Card quantity is between 1 1100 of the 8 digits c...

Page 11: ...d 2 Note This is done outside of programming mode so a user can undertake this themselves User ID number Old PIN New PIN New PIN To delete a Card and PIN user just delete the card 2 Read card or 2 Use...

Page 12: ...ically Door Forced Open warning When used with and optional magnetic contact or built in magnetic contact of the lock if the door is forced open or if the door is opened after 120 seconds of the elect...

Page 13: ...to operate the doorbell The wiring is connecting the doorbell to COM2 and NO2 Press the keypad will send the signal to the doorbell Zone 2 8 8 Factory default Doorbell 8 9 Remove the alarm To remove t...

Reviews: