Card and Pin Mode 

To set user for Zone 1 (  3  1  1  #  ) 

To add a card and PIN user 
(The PIN is any 4-6 digits between 0000-999999 
except for 1234 which is reserved) 

Add the card user Press 

 to exit from the programming 

mode then allocate the card a PIN as follows:  

 

  Read card  1234#  PIN#  PIN#

 

To 

change a PIN

 in card and PIN mode (Method 1) 

Note: this is done outside of programming mode so 
a user can undertake this themselves. 

  Read card  Old PIN#  New PIN#  New PIN# 

To 

change a PIN

 in card and PIN mode (Method 2) 

Note: This is done outside of programming mode so 
a user can undertake this themselves. 

  User ID number#  Old PIN#  New PIN#  New PIN#

 

To delete a 

Card and PIN

 user just delete the card 

2  Read card  #  or  2  User ID  #

 

To set users for Zone 2 (  3  2  1  #  ) the operation is the same as Zone 1 

Card only Mode

 (in this mode, users can only be valid by card) 

To set Card user only 

3  1  0  # , Zone 1 
3  2  0  # , Zone 2 

With this setting entry is by Card only 

To delete

 

ALL users

 

Note: This is a dangerous option, so use with care 

Delete al users of Zone 1:  2  0000  # 
Delete all users of Zone 2:  9  0000  # 

 

To unlock the door 

(or change the relay state)

 

For a 

PIN

 user 

Enter the  PIN  then press  # 

For a 

Card

 user 

Read card 

For a 

Card and PIN

 user 

Read card  then enter the  PIN 

 

 

 

Summary of Contents for GTR057

Page 1: ...GTR057 Installation Manual Rev 2 1 Metal Waterproof Access Keypad GTR057 Suits the Following Richmond Gate Motors GTR064 GTR207 GTR061 GTR156 GTR212 GTR099 GTR058...

Page 2: ...to 1100 PIN Card holders Zone 2 up to 100 PIN Card holders PIN Length 4 6 digits Card type 125KHz EM card Can be used as a standalone keypad Pulse mode Toggle Mode Block enrolment can enrol 1100 conse...

Page 3: ...1 User ID Number PIN For Zone 2 1 User ID Number PIN The ID number is any number between 1 1100 for Zone 1 and any number between 1101 1200 for Zone 2 Users can be added continuously without exiting p...

Page 4: ...Installation Manual Rev 2 4 How to connect to the GTR156 GTR212 control board The below diagram shows how to connect the wires from the GTR057 wired keypad to the GTR156 GTR212 Automatic Slide Gate O...

Page 5: ...lation Manual Rev 2 5 How to connect to the GTR061 GTR064 GTR207 control board The below diagram shows how to connect the wires from the GTR057 wired keypad to the GTR061 GTR064 GTR207 Automatic Slide...

Page 6: ...GTR057 Installation Manual Rev 2 6 How to connect to the GTR099 control board The below diagram shows how to connect the wires from the GTR057 wired keypad to the GTR099 Automatic Swing Gate Opener...

Page 7: ...GTR057 Installation Manual Rev 2 7 How to connect to the GTR058 control board The below diagram shows how to connect the wires from the GTR057 wired keypad to the GTR058 Automatic Swing Gate Opener...

Page 8: ...relay changes state which will not turn back until read card or input PIN again 10 Reset to Factory Default To reset to the factory default power off press hold it and power on release it until you he...

Page 9: ...the working mode Card PIN or Card PIN Set valid Card or PIN users 3 1 2 Zone 1 3 2 2 Zone 2 Entry is by either Card or PIN Factory default setting Set valid Card and PIN users 3 1 1 Zone 1 3 2 1 Zone...

Page 10: ...cards users Block Enrolment The card numbers must be consecutive This operation is only for Zone 1 5 User ID number 8 digits Card number Card quantity Card quantity is between 1 1100 of the 8 digits c...

Page 11: ...d 2 Note This is done outside of programming mode so a user can undertake this themselves User ID number Old PIN New PIN New PIN To delete a Card and PIN user just delete the card 2 Read card or 2 Use...

Page 12: ...ically Door Forced Open warning When used with and optional magnetic contact or built in magnetic contact of the lock if the door is forced open or if the door is opened after 120 seconds of the elect...

Page 13: ...to operate the doorbell The wiring is connecting the doorbell to COM2 and NO2 Press the keypad will send the signal to the doorbell Zone 2 8 8 Factory default Doorbell 8 9 Remove the alarm To remove t...

Reviews: