Rice Lake RS-130 Operation Manual Download Page 8

RS-130/RS-160 Price Computing Retail Scale

4

Visit our website 

www.RiceLake.com

1.4

Start-up Self Check

Figure 1-2. ON/OFF Switch 

Location

The RS-130/RS-160 must charge for 24 hours prior to operation. Turn on the scale using the 

ON/OFF

 switch on the bottom, right side of the scale. The main program provides the 

following display check. 

• Shows the total capacity (30 or 60) in the WEIGHT display 
• Counts from one to nine in each display window
• Displays the total capacity (30 or 60) in the WEIGHT display again 
• Displays 0.00 for operation

1.5

Power Supply

The RS-130/RS-160 can use power supplied by either a plug-in 110 VAC or the internal 

sealed, lead-acid rechargeable battery with a life expectancy of five years under normal use. 

• AC - 110V/60Hz ±10% (battery recharging only)
• DC - 6V / 25mA; P=0.2W (max) 4Ah

1.6

Battery Recharging

The battery has 100+ hours of use before it needs recharging. When the battery is low, the total display shows 

-LO- 

and there 

are three beeps. After the initial warning of low battery, the scale has approximately two to three hours of battery life left. If the 

battery is not charged, the scale will beep and then shut down. To recharge the battery, allow eight to ten hours for a full charge. 

Table 1-2 describes the Charge LED colors.

Red

Initial connection

Orange

Charging

Green

Fully-charged

1.7

Setting the Auto-Off Feature

Note

  Work inside scale enclosure is not required.

1. Turn on the scale while pressing 

CHANGE

 until 6.3 displays (approximately three seconds).

2. Press and hold 

ZERO

 until SETUP displays in WEIGHT (approximately three seconds).

3. Press 

USUAL displays.

4. Press 

 to enter the Auto-Off mode. -OFF- displays.

5. Use 

CLEAR

 to select -30-, -15-, -5- or -OFF-.

6. Press 

CHANGE

 to confirm setting. The scale will automatically restart.

LED Color

Description

Table 1-2.   Battery Charge LEDs

Summary of Contents for RS-130

Page 1: ...RS 130 RS 160 Price Computing Retail Scale Version 2 0 Operation Manual RS 130 Model Shown PN 169634 Rev A August 29 2018...

Page 2: ...marks of their respective companies All information contained within this publication is to the best of our knowledge complete and accurate at the time of publication Rice Lake Weighing Systems reserv...

Page 3: ...Feature 4 2 0 Setup 5 2 1 Unpacking 5 2 1 1 Components 5 2 2 Leveling the Scale 5 2 3 Assemble Pole Type Scale 6 2 4 Power Scale 6 2 5 Setup Functions 7 2 5 1 Auto Back Light Enable Disable 7 2 5 2 Ke...

Page 4: ...Price Computing Retail Scale ii Visit our website www RiceLake com Rice Lake continually offers web based video training on a growing selection of product related topics at no cost Visit www ricelake...

Page 5: ...can be found on the website at www ricelake com warranties 1 1 Overview The RS 130 RS 160 retail scale offers practical solutions for a full range of point of sale weighing and price computing applic...

Page 6: ...perate or work on this equipment unless this manual has been read and all instructions are understood Failure to follow the instructions or heed the warnings could result in injury or death Contact an...

Page 7: ...b or oz in weighing mode See Section 3 2 on page 8 13 Change Key computes the amount of change to be given back to a customer for their purchase See Section 3 5 on page 10 14 Tare Key acquires the net...

Page 8: ...1 6 Battery Recharging The battery has 100 hours of use before it needs recharging When the battery is low the total display shows LO and there are three beeps After the initial warning of low batter...

Page 9: ...e Lake Weighing Systems and the shipper immediately 2 1 1 Components Figure 2 1 RS 130 RS 160 Scale Components RS 130 shown Scale Pan Power cord Pole pole type only Upper display pole type only 2 2 Le...

Page 10: ...the nut securely Figure 2 4 Connect and Mount Display 5 Carefully open the upper display by snapping the two sides apart 6 Plug the cable into the display board 7 Snap the two sides back together 8 Re...

Page 11: ...UP displays 3 Press USUAL displays 4 Press the scale beeps twice for enable once for disable and good flashes twice 2 5 3 Unit Price Auto Clear Enable Disable 1 Turn on the scale and press and hold CH...

Page 12: ...Unit Price Display lb 1 Press UNIT ch9 displays 2 Using the numeric keypad enter 1 to select kg 2 to select lb default 3 to select oz The annunciator flashes above the selected unit of measure in the...

Page 13: ...1 0 61 NET displays 3 4 M1 M9 Keys There are nine memory keys available to save UNIT PRICE TARE WEIGHT and UNIT OF MEASURE values Figure 3 5 Memory Keys 1 Choose the UNIT of MEASURE see Section 3 2 on...

Page 14: ...ue The TOTAL displays 20 00 cash received 3 6 Clear Press CLEAR to erase a value displayed in the UNIT PRICE 3 7 Decimal Point Set the decimal point This feature available on SN B00551 or higher only...

Page 15: ...the platter is more than 5 of the maximum capacity Remove the weight from the scale or lighten the weight to under 5 of capacity and restart the scale TOTAL display shows E Total price value is large...

Page 16: ...RS 130 RS 160 Price Computing Retail Scale 12 Visit our website www RiceLake com...

Page 17: ......

Page 18: ...nada Mexico 800 321 6703 International 715 234 9171 Europe 31 0 26 472 1319 Rice Lake Weighing Systems is an ISO 9001 registered company Rice Lake Weighing Systems Specifications subject to change wit...

Reviews: