![Rice Lake RS-130 Operation Manual Download Page 8](http://html1.mh-extra.com/html/rice-lake/rs-130/rs-130_operation-manual_1454233008.webp)
RS-130/RS-160 Price Computing Retail Scale
4
Visit our website
1.4
Start-up Self Check
Figure 1-2. ON/OFF Switch
Location
The RS-130/RS-160 must charge for 24 hours prior to operation. Turn on the scale using the
ON/OFF
switch on the bottom, right side of the scale. The main program provides the
following display check.
• Shows the total capacity (30 or 60) in the WEIGHT display
• Counts from one to nine in each display window
• Displays the total capacity (30 or 60) in the WEIGHT display again
• Displays 0.00 for operation
1.5
Power Supply
The RS-130/RS-160 can use power supplied by either a plug-in 110 VAC or the internal
sealed, lead-acid rechargeable battery with a life expectancy of five years under normal use.
• AC - 110V/60Hz ±10% (battery recharging only)
• DC - 6V / 25mA; P=0.2W (max) 4Ah
1.6
Battery Recharging
The battery has 100+ hours of use before it needs recharging. When the battery is low, the total display shows
-LO-
and there
are three beeps. After the initial warning of low battery, the scale has approximately two to three hours of battery life left. If the
battery is not charged, the scale will beep and then shut down. To recharge the battery, allow eight to ten hours for a full charge.
Table 1-2 describes the Charge LED colors.
Red
Initial connection
Orange
Charging
Green
Fully-charged
1.7
Setting the Auto-Off Feature
Note
Work inside scale enclosure is not required.
1. Turn on the scale while pressing
CHANGE
until 6.3 displays (approximately three seconds).
2. Press and hold
ZERO
until SETUP displays in WEIGHT (approximately three seconds).
3. Press
, USUAL displays.
4. Press
to enter the Auto-Off mode. -OFF- displays.
5. Use
CLEAR
to select -30-, -15-, -5- or -OFF-.
6. Press
CHANGE
to confirm setting. The scale will automatically restart.
LED Color
Description
Table 1-2. Battery Charge LEDs