RL-TA Series Operation Manual 65
17.4.4
Set measurement mode command
Command Main Body
Description
Value
Response
first
character
second
character
ASCII code
M
1
4DH
31H
Set to Mode 1
None
A00: Successful
completion
E01: Command error
E02: (error)
M
2
4DH
32H
Set to Mode 2
M
3
4DH
33H
Set to Mode 3
M
4
4DH
34H
Set to Mode 4
* The measurement mode to be activated by the above mode settings 1 to 4 depends on the weighing mode
currently in use.
Mode
setting
Weighing
machine
Parts counting
Percentage
weighing
Unit converting
Gravi-
meter
Mode 1
Weight
measuring
Weight
measuring
Weight
measuring
Weight
measuring
(Error)
Mode 2
Gross weight
Parts counting
Percent
measuring
Coefficient
multiplying
(Error)
Mode 3
Cumulative
weight
*1
Cumulative
count
*1
Cumulative
percent
*1
Cumulative
sum
*1
(Error)
Mode 4
Display in unit
B
*2
Average unit
weight
(Error)
(Error)
(Error)
*1 Mode 3 (M3) can be specified only when the addition function is to be used. If the addition function is
not enabled, it results in an error.
*2 If a unit is not specified for unit B, the balance is set for the weight measuring mode.
When you specify a mode that is not supported by the current Weighing Mode, an error is returned from
the balance.
17.4.5
Request date or time output command
Command Main Body
Description
Value
Response
first
character
second
character
ASCII code
D
D
44H
44H
Date output request
None
A00: Successful
completion
E01: Command error
D
T
44H
54H
Time output request
(1) Date format
DATE:yyyy.mm.dd(CR)(LF)
English
ヒヅケ
:yyyy.mm.dd(CR)(LF) Japanese (Katakana)
(2) Time data
TIME:(SP)(SP)(SP)(SP)(SP)hh:mm(CR)(LF) English
ジコク
:(SP)(SP)(SP)(SP)(SP)hh:mm(CR)(LF)
Japanese (Katakana)