![Rice Lake MSI-8000 Technical Manual Download Page 41](http://html.mh-extra.com/html/rice-lake/msi-8000/msi-8000_technical-manual_1453937041.webp)
ScaleCore Connect
©
Rice Lake Weighing Systems
●
All Rights Reserved
37
3.3.7 Stream Print String
Listeners
The
Listeners feature controls the machine to machine communications interfaces.
Figure 3-37. Listener Settings
1. Select
Inputs / Outputs
, then
Stream Print String
.
2. Select the
Listeners
tab.
3. Enter the following parameters:
Listener Number
– select stream listener number from 0-2
Destination ID
– select the ID assigned to the stream listener from 0-255; 255 indicates broadcast ID, it is for every
device that attached
Sensor ID
– select the sensor the listener will observe from 1-5
Stream Type
– select the type of this stream listener
Interval in 50mSec
– select interval value from 0-255;
example, 20 means 20x50milliSec = 1 second
Control Output Mode
– select the mode for the listener
4. Press
to save.