1.7 MSI-7001 Front Panel
Figure 1-2. MSI-7001 Front Panel
Item No.
Description
1
Output / Input – Type is checked
2
RF Frequency – Type is checked
3
Transmitter Power LED – Indicates state of unit power
Steady short green blinks – Good battery (or AC power)
Two red blinks then a pause – Low battery
Four red blinks then a pause – Very low battery
Steady red – Load cell fault (overload/underload/uncal/error/etc.)
Five green blinks per second – Calibration mode
Receiver Power LED – Indicates state of unit power
Steady short green blinks – RF connected, good battery (or AC power)
Two short red blinks then a pause – RF connected, low battery
Four short red blinks then a pause – RF connected, very low battery
Steady long red blinks – RF disconnected and good battery (or AC power)
Long red blink, short red blink then a pause – RF disconnected and low battery
Long red blink, three short red blinks – RF disconnected and very low battery
NOTE: Older units have a single color red LED and newer units have a dual color red and green LED. Blinking patterns are
consistent for all units.
4
Power Button
Press & release – Turns unit on
Press & hold 1-4 seconds – Will auto zero
Press & hold 5 seconds – Turns unit off
5
Power Input – Located on the side of the unit; Type is checked
6
Serial Port – Located on the side of unit; Pre-set at 9600 baud and 8-N-1
Table 1-4. MSI-7001 Front Panel Controls
Sensor In
Power In
Serial
Port
85~265 VAC
47~63 Hz
7~36 VDC
EXT BATTERY
5~6 VDC
Load Cell In
mV/V Out
802.15.4
WiFi 802.11
FHSS
2
1
3
4
5
6
Measurement Systems
International
TM
A RICE LAKE WEIGHING SYSTEMS COMPANY
MSI-7001
Made in the U.S.A
Blink Rate
1/s = Power OK
2/s = Low
4/s = Very Low