4.6 Setpoints
The MSI-4260M supports eight user programmable setpoints. Common uses of setpoints are for warnings or process control.
Setpoints 1-3 are visible on the device and have LED outputs that can be setup in the RF menu (
).
Setpoints 4-8 can only be used by connecting a compatible RF remote rontrol or RF remote display.
Figure 4-2. Setpoint LEDs
The MSI-4260M has an audible output option that is triggered by Setpoint 1. Contact Rice Lake Weighing Systems for other
setpoint output options. To set the setpoint:
1. Press and hold
and
.
displays.
2. Press
to scroll to the desired setpoint (
).
3. Press
. The current
mode displays.
4. Press
to scroll to the setpoint mode desired.
5. Press
. The current
weight type displays.
6. Press
to scroll to the desired weight type.
7. Press
. The current setpoint weight value displays.
8. Press
. The first digit blinks.
9. Press
to scroll to the desired number.
10. Press
. The second digit blinks.
through
until the desired value displays.
To enter a decimal point, press
while the digit is blinking. To correct a digit, press
.
12. Press
. The value stops blinking and the next setup menu item displays.
through
to set all the setpoints to be used.
14. Press
to exit setup and store the settings.
Press
at any time to cancel the procedure.
Setpoint
Description
Setpoint Mode
Indicates the setpoint triggers when the weight exceeds a set value
Indicates the setpoint triggers when the weight is less than a set value
Setpoint Weight Type
Responds to net or gross weight
Responds to gross weight regardless of the display
Responds to the totaled weight
Responds to the total count (number of samples)
Responds to the number of times the weight has exceeded 25% of capacity