Installation
7
Figure 2-7. Location of Top Cover Screws
6. Disconnect black (
–
) and red (
+
) electrical
leads from battery (see Figure 2-8). Remove
existing DC battery pack.
7. Place new DC battery pack in battery
compartment.
8. Attach red lead to positive (
+
) side of battery.
9. Attach black lead to negative (
–
) side of
battery.
Figure 2-8. Battery Installation
10. Reassemble scale in the reverse order that it
was disassembled.
11. Remove setscrew to unlock scale before
placing the scale into service.
If the IQ9500 scale is operated with the
battery pack removed, isolate the
positive (+) and negative (–) leads so
that they do not make contact with each other or any part
of the scale frame or any sensitive electronic
components.
2.5.3
DC Battery Operation
To power-up the IQ9500 using the optional battery:
1. Remove AC power cord from bottom of scale.
2. Turn battery switch to ON (located on the
bottom left-hand side of the scale base).
3. Press
ON/OFF
and allow scale to warm up for
10 minutes. The display momentarily shows
revision number, shows all digits from 0 to 9
in a count-up mode, goes blank, shows all 8s,
and then enters normal weighing mode.
2.5.4
Battery Charging
A fully charged battery allows for approximately 4
hours of continuous use. Refer to SPEC 1 (
Power
Auto Off Function
) for extended hours of use. It will
take approximately 8 hours to fully recharge a battery
that has been completely dissipated. The console must
be connected to the base during the recharge cycle and
the AC power cord must be plugged in.
Do not store the scale without turning off the battery
power switch. When the battery switch is
ON
and the
AC is not connected, a low level battery current will
flow even if the display is
OFF
. To prevent battery
discharge when stored, turn the battery switch
OFF
whenever the unit is not in use.
2.6
Setting Time and Date
You can set the time and date that you want to appear
on IQ9500 print tickets. SPEC 5, bits 0 and 1 list three
sequence variations of year, month, day that are
available to program into the IQ9500 counting scale.
To set the date (month, date, and year) and time:
1. Press the
MODE
key.
2. Press the
–/DATE
key. The displays shows the
date, day and time.
3. Press the
–/DATE
key again. Enter month, day,
year (mmddyy) on the keypad.
4. Press the
–/DATE
key. Enter the day (0=Mon,
1=Tue…6=Sun.
5. Press the
–/DATE
key. Enter the time of day
using the 24-hour clock. For example, enter
1:35 p.m. as 1335.
6. Press the
*/PROG
key to store the setting, or
press the
–/DATE
key to exit without saving
time and date.
TOP COVER SCREWS
BATTERY
POSITIVE (+)
TERMINAL
NEGATIVE (-) TERMINAL
!
Caution