8. Dress properly 
When installing, do not wear loose clothing or jewellery; they can be caught in moving parts.  
Wear protecting hair covering to contain long hair. 
9. Use protective equipment 
When installing, wear protective equipment appropriate to working conditions and work environment 
Wear protective helmet, safety goggles, ear mufflers, face or dust mask, rubber gloves and non-skid 
footwear to reduce the risk of personal injury during products use or manipulation. 
10. Do not abuse the power cable 
Never carry the product by the cable or yank it to disconnect it from the socket.  
Keep the cable away from heat, oil and sharp edges. 
Inspect product cable periodically and if damaged have it repaired by an authorized service facility.  
Inspect extension cords periodically and replace, if damaged.  
11. Do not overreach 
When installing, keep proper footing and balance at all times. 
12. Maintain product with care 
Keep product clean for better and safer performance.  
13. Disconnect product 
When not in use, before servicing and when changing accessories. 
14. Avoid unintentional starting 
Ensure switch is off when plugging in. 
15. Use of extension leads  
When product is used with extension cord, ensure that extension cord withstands product ratings. 
If used outdoors, use only extension cords intended for outdoor use. 
16. Stay alert 
Watch what you are doing. Use common sense.  
Do not operate product when you are tired, under the influence of alcohol, prescription medicines or 
drugs. 
17. Check damaged parts 
Before further use or reuse of the product, it should be carefully checked to determine that it will 
operate properly and perform its intended function.  
18. Defective switches or other part that is damaged should be properly repaired or 
replaced by an authorized service centre. Do not use the product if the switch does not turn it on and 
off. 
19. Warning 
The use of any accessory or attachment, other than those recommended in this instruction manual, 
may present a risk of injury to persons or animals and may cause damages. 
The user and/or operator are responsible for any damages or injury caused to properties and/or 
persons. 
20. Have your product repaired by a qualified person 
Unless otherwise indicated in this instruction manual, repairs or replacement of any damaged part in 
an authorized service centre is recommended. 
This electric product is in accordance with the relevant safety requirements. Repairs should only be 
carried out by qualified persons using original spare parts, otherwise this may result in considerable 
danger to the user. 
21. Remarks: 
The safety precautions and instructions given in this manual are unable to cover in detail all the 
conditions and situations that may arise.  
The operator and/or user must use common sense and caution when operating the product especially 
for any matters that are not referred in the above 
 

Summary of Contents for Ribiland PRPVC1101/65F

Page 1: ...P User and maintenance manual IT POMPA SOMMERSA Manuale di istruzioni e di manutenzione R f Art Nr PRPVC751 43F 510941 R f Art Nr PRPVC1101 65F 510976 Imp par by Ribimex S A 56 Route de Paris FR 77340...

Page 2: ...e injury and or damages Please keep this manual for future reference AVVERTENZA Leggere attentamente questo manuale di istruzioni prima di utilizzare l attrezzo Il funzionamento non corretto pu causar...

Page 3: ...nder conseil aux autorit s locales ou votre d chetterie locale 3 1 LIRE TOUTES LES INSTRUCTIONS AVANT D UTILISER CE PRODUIT 1 Garder l aire de travail propre Des aires de travail et des tablis encombr...

Page 4: ...r changer les accessoires 14 Eviter les d marrages intempestifs S assurer que l interrupteur est en position arr t avant de brancher la source d alimentation 15 Utilisation de rallonge Lorsque le prod...

Page 5: ...duel DDR de courant diff rentiel de fonctionnement assign n exc dant pas 30 mA Installer le bo tier de contr le avant toute utilisation Consulter un lectricien qualifi 3 Le c ble d alimentation doit t...

Page 6: ...ieure 0 1 proportion de la qualit et le diam tre des particules doit tre inf rieur 0 2 mm 9 La pompe submersible ne doit pas tre utilis e dans les piscines 10 CONSEIL L installation peut tre une op ra...

Page 7: ...rieure 50cm Il est recommand d installer une grille de protection autour de la pompe pour emp cher les contre les impuret s ou mati res trang res telles que mauvaises herbes ne bloquent le filtre et p...

Page 8: ...ec l ensemble des r gles de s curit et les exigences du moteur V rifier la valeur du fusible ou disjoncteur et le protecteur contre les surcharges V rifier que tous les tuyaux en m tal et le bo tier d...

Page 9: ...ise entre 0 7 1 2 fois la port e nominale sinon le fonctionnement de la pompe est dans un tat anormal de sorte que le moteur risque de surchauffer voire br ler 7 Si un ph nom ne anormal appara t comme...

Page 10: ...t compl tement immergeable la profondeur d immersion ne doit pas d passer 15m se r f rer au tableau des caract ristiques techniques 3 Cette pompe ne doit pas tre utilis e pour aspirer des liquides ou...

Page 11: ...u claire de la pompe y compris le circuit d aspiration Apr s avoir utilis la pompe dans une piscine ou un plan d eau veillez la rincer l eau claire y compris le circuit d aspiration 3 Avant chaque rem...

Page 12: ...ctrique faites appel un sp cialiste 2 Lib rer et nettoyer la turbine 3 faites remplacer le stator par un service agr Bobinage du stator grill 1 La pompe a fonctionn trop longtemps avec une phase perdu...

Page 13: ...ther information for its safe disposal 3 1 READ ALL THE INFORMATION BEFORE OPERATING THE PRODUCT 1 Keep work area clean Cluttered areas and benches invite accidents and injuries 2 Consider work area e...

Page 14: ...lert Watch what you are doing Use common sense Do not operate product when you are tired under the influence of alcohol prescription medicines or drugs 17 Check damaged parts Before further use or reu...

Page 15: ...connector for the extension should be of the 2 poles earth of type 10 16A 250V in accordance with IEC and European standards The wire section in the cable should be equal to or greater than 1mm2 The c...

Page 16: ...e pump to be lifted in and out f Caution If there is any doubt about the safety of the pump do not use it 4 1 Unpacking 4 1 1 Check the pump 1 Remove product from its packaging and check that product...

Page 17: ...ufacturer i e 30m 2 If the distance to power supply is far it is recommended to use a bigger diameter cable The insulation resistance of motor stator winding should be over 5mega Ohm 3 It is first rec...

Page 18: ...to prevent loosening due to the torque of motor 4 6 Operation 1 Before starting the pump check the direction of motor rotation trial run the pump for no more than 1 minute to check the motor rotates c...

Page 19: ...rtening the length of the cable between the pump and the float it is possible to modify the water heights that trigger starting and stopping of the pump 7 To adjust the cut in cut out height fix the f...

Page 20: ...d lock the float switch To operate the pump press the On Off switch b For temporary installation Raise the float switch to start the pump and lower it to stop the pump Note in this two cases the minim...

Page 21: ...department your dealer otherwise we decline responsibility 9 You are advised to check the following periodically The condition of the cables and grommets especially at their attachment 6 2 Breakdown N...

Page 22: ...ousehold garbage Do not throw into the environment Dispose of the product in a collection centre for waste of electrical and electronic equipment or a waste drop off centre or seek advice from your lo...

Page 23: ...ggio Contattare l ente locale preposto o l azienda incaricata per ulteriori informazioni sul metodo sicuro di smaltimento 3 1 LEGGERE TUTTE LE INFORMAZIONI PRIMA DI UTILIZZARE IL PRODOTTO 1 Mantenere...

Page 24: ...ndo l attrezzo utilizzato con un estensione utilizzare soltanto estensioni concepite e previste per sopportare la corrente che alimenta l attrezzo 16 Fare sempre attenzione Guardare quello che si fa P...

Page 25: ...un elettricista qualificato 3 Controllate periodicamente il cavo di alimentazione prima di ogni uso e verificare se presenta segni di invecchiamento o danni Se la pompa non in buone condizioni non met...

Page 26: ...a Si deve quindi essere effettuata da persone competenti e autorizzate 11 Attenzione durante l installazione si applicano tutte le norme di sicurezza emanate dalle enti locali competenti e usare il bu...

Page 27: ...C 104F Si dovrebbe quindi ridurre il carico del motore o aumentare la quantit di acqua per evitare il surriscaldamento del motore 4 Non richiesto installare una valvola di non ritorno sulla tubazione...

Page 28: ...in un luogo chiuso con emissione di fumi nocivi ad esempio fosse settiche serbatoio l impianto deve essere in conformit con le leggi locali e o le leggi federali da parte di personale qualificato al...

Page 29: ...agli animali domestici nell area di lavoro della pompa per circa due metri quadrati 9 E rigorosamente vietato toccare la pompa quando essa collegata alla rete al fine di evitare incidenti 4 7 Galleggi...

Page 30: ...nstalazione permanente Sollevate e bloccare il galleggiante La pompa si avvia e si ferma quando si preme sull interruttore b instalazione temporanea Sollevate il galleggiante per avviare la pompa rila...

Page 31: ...aro altrimenti il declino di responsabilit 9 Si consiglia di controllare periodicamente i seguenti componenti la condizione dei cavi e anelli soprattutto il loro collegamento 6 2 Ricerca guasti Non te...

Page 32: ...ifiuti domestici o nell ambiente naturale Portare il prodotto ad un centro per il trattamento dei rifiuti o ad un centro di colletta degli scarti delle attrezzature elettriche ed elettroniche o inform...

Page 33: ...refoulement 7 Points de fixation 8 Pompe submersible 9 Orifices d aspiration 10 Interrupteur flottant 1 Power cord with plug 2 Control box to pump cable 3 Control box 4 ON OFF switch 5 Circuit breake...

Page 34: ...crizione Pompe automatique submersible pour eaux claires Automatic Submersible clear water pump Pompa sommersa automatica per acque chiare R f rence Reference Articolo PRPVC751 43F 510941 PRPVC1101 65...

Reviews: