3
Directions for maintenance & use
SURPRESSOR PUMP MH
WARNING!
In order to reduce the risks of fire, electric shock and personal injury during the course of
installation and use of your pump, it is recommended that you always adhere to basic safety precautions,
including the following:
Read these instructions in their entirety before operating this machine and retain these instructions,
1)
GENERAL REMARKS
The water pump is designed to suck up treated water.
The pump must be installed in a dry, ventilated location, not exposed to bad weather and heat; the maximum
suction height must not exceed 8 meters.
When correctly installed, your pump will operate with maximum efficiency and entirely to your satisfaction:
be sure to read the following instructions carefully.
2)
TECHNICAL DATA
The specifications set out below are the same irrespective of the tank supplied:
Model
MH400
MH600
MH800
MH1000
Max. H
20 M
31 M
42 M
53 M
Max Q
60 l/min
60 l/min
60 l/min
60 l/min
Motor power
450 W
600 W
800 W
1000 W
Model
MH700
MH900
MH1100
MH1300
Max. H
25 M
35 M
45 M
55 M
Max Q
90 l/min
90 l/min
90 l/min
90 l/min
Motor power
700 W
900 W
1250 W
1450 W
Model
MH1500-3M
MH1800-4M
MH2200-5M
Max. H
36 M
48 M
58 M
Max Q
170 l/min
170 l/min
170 l/min
Motor power
1500 W
1800 W
2300 W
Model
MH1500-6M
MH1800-8M
MH2500-10M
Max. H
65 M
85 M
105 M
Max Q
90 l/min
90 l/min
90 l/min
Motor power
1650 W
2100 W
2650 W
3)
USE AND INSTALLATION
a)
Use:
The water pump is designed for everyday uses such as gardening, sprinkler systems, increasing water
pressure of the non-feed water distribution network, pumping of tank water and jet washing. The
pump/booster assembly maximizes water storage by limiting frequency of operation, and in particular
ensures constant pressure is maintained in the installation.
The pump must not be operated for uses not specified in this manual.
In particular, the pump must not be use for:
- Pumping of seawater, waste water, water containing solid bodies, sand or abrasive particles in
suspension, or water containing corrosive substances in general.
- Pumping of water whose temperature exceeds 35ºC
- Pumping of explosive, inflammable or dangerous liquids.
b)
Major recommendations:
Before connecting up to the electricity network, you must:
- Fasten the pump securely to the ground or a suitable support.
With that in mind, the four feet of the tank have been perforated so as to allow fastening bolts (not
supplied) to go through.
-
Ensure that the network voltage is the same as that stated on the pump specification label.
ATTENTION!
GB