background image

The user and/or operator are responsible for any damages or injury caused to properties 
and/or persons. 
14.7. Remarks 
The safety precautions and instructions given in this manual are unable to cover in detail 
all the conditions and situations that may arise.  
The operator and/or user must use common sense and caution when operating the product 
especially for any matters that are not referred in the above 

 
3.2- Safety precautions  
Initial preparation before operation 

- When you operate the blower, always wear full-length trousers, as well as sturdy, closed shoes 
that provide good support. 
- Under no circumstances should jewelry, any other body ornamentation, or loose clothing be worn 
while operating the device as these items could be drawn into the suction orifice. When working 
outdoors, rubber gloves and n on-slip footwear should always be worn. If you have long hair, put it 
in a hair net. 
- Wear protective equipment and always wear protective goggles.  
Wearing protective equipment such as a dust mask, non-slip footwear, protective gloves, a helmet 
and/or hearing protection (depending on the type and application of the electrical device concerned) 
reduces the risk of injury.  
- When performing work that generates dust, wear a dust protective mask.  
- Each time you use the blower, check the integrity of the product’s power cord and your own 
extension cord. The product should only be operated when its accessories are in perfect working 
order. Any damaged or defective components should be repaired immediately by a qualified 
technician. 
Under no circumstances should the blower be operated while safety devices or protections are 
damaged or if safety equipment such as a deflection device or collection bag are not installed. 
- Only extension cords that are rated for outdoor use should be used outdoors. 
Any extension cord used should measure a minimum cross section of 1.5mm2. All plug-in 
connections should have an earth contact and water-spray shielding. 
 

During use 

- Make sure the power cord is kept behind and away from the device while you work. 
- If the power cord or extension cord are damaged while you work, unplug the blower immediately. 
DO NOT TOUCH THE CABLE BEFORE UNPLUGGING IT FROM ITS POWER SOURCE. 
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or 
similarly qualified persons in order to avoid a hazard. 
- Never use the power cord as a handle to lift or carry the device. 
- Always unplug the product under the following circumstances: 
 

. When the blower is not in use, is being carried/transported, or is left unattended. 

 

. While examining, cleaning or unclogging the product. 

 

. When cleaning the product, performing maintenance on it, or attaching accessories to it. 

 

. If the device strikes a foreign object (e.g. fence…) or begins vibrating abnormally.  

- If product bumps into any object during operation, stop it and control that it has not been damaged. 
Replace or repair any damaged piece in a qualified service centre. 
- Use the blower in daylight or with adequate illumination. 
- Do not overreach. Keep proper footing and balance at all times. 
- Bear in mind that the force generated by an electrical device can make you lose your balance. 
Therefore, make sure that your feet are firmly planted and that your body is well balanced when 
you are operating the product. 
- Never operate the blower on damp or wet grass. 
- Use of the blower on sloping areas:  

Summary of Contents for 514506

Page 1: ...VACUUM MULCHING BLOWER User and maintenance manual IT ASPIRATORE TRITURATORE SOFFIATORE Manuale di istruzioni e di manutenzione DE LAUBSAUGER BL SER Bedienungs und Wartungsanleitung ES SOPLADOR ASPIRA...

Page 2: ...VVERTENZA Leggere attentamente questo manuale di istruzioni prima di utilizzare l attrezzo Il funzionamento non corretto pu causare lesioni e o danni Conservare il presente manuale per futuri consulti...

Page 3: ...ctor lever 7 Motor casing 8 Main handle 9 ON OFF switch 10 Speed Control 11 Power cord 12 Auxiliary handle II CHARACT RISTICS Description Vacuum blower Reference PRASB2400 3 514506 Model EB8612 GY8612...

Page 4: ...source if product power cable or extension cord is damaged or cut during operation Unplug product by pulling the plug Do not pull the cable Do not dispose of this product with household rubbish Dispo...

Page 5: ...Instructions Manual should be performed by competent service personnel 9 Always switch off the engine before setting it down 10 Do NOT expose to and do not use during bad weather conditions never work...

Page 6: ...d while safety devices or protections are damaged or if safety equipment such as a deflection device or collection bag are not installed Only extension cords that are rated for outdoor use should be u...

Page 7: ...AC outlet with 10 amps of fuse protection The electrical outlet is to be protected by an earth leakage circuit breaker ELCB with a max triggering current of 30mA Before starting the product Only opera...

Page 8: ...urpose The device is only to be used on dry surfaces The device is intended for non commercial use in private home and gardens Under no circumstances is it to be used in public outdoor areas sports st...

Page 9: ...ou remove and empty the leaf bag ensure that the machine has been disconnected from the mains power supply To empty the leaf bag simply open the zip fastener empty the bag and then close the zip faste...

Page 10: ...bag Product must be stored in a dry well ventilated location Always lock up product and keep out of reach of children 6 4 Disposal When disposing of your machine be sure to follow the local regulation...

Page 11: ...9 Interruttore 10 Regolattore di velocita 11 Cavo elettrico 12 Manico aussiliario II CARATTERISTICHE Descrizione Aspiratore Trituratore Sofiatore Articolo PRASB2400 3 514506 Modello EB8612 GY8612 Alim...

Page 12: ...ttrico se il cavo o il prodotto si danneggia durante l uso Scollegare il prodotto estraendo la spina dalla presa Non tirare il cavo Non smaltire questo attrezzo come normale rifiuto urbano Gli attrezz...

Page 13: ...he il tubo non sia ostruito con oggetti 8 Tutti gli interventi sul prodoto salvo quelli specificamente indicati in questo manuale devono venire fatti solo da personale specializzato 9 Prima di deporre...

Page 14: ...raccolta e o deviazione per l erba Durante il lavoro all aperto usare esclusivamente prolunghe omologate per questo scopo Le prolunghe usate devono avere un diametro minimo di 1 5 mm I collegamenti de...

Page 15: ...so che il soffiatore aspiratore non presenti segni di danneggiamento Prima di ogni messa in funzione necessario controllare il cavo di collegamento per escludere la presenza di danni Il cavo deve esse...

Page 16: ...effettivamente necessario L uso di cavi di prolunga pu causare cadute di tensione che possono a loro volta causare perdita di potenza dell apparecchio o un surriscaldamento del motore Accensione speg...

Page 17: ...er evitare che ci accada utilizzare il fermo per prolunga VI PULIZIA E CONSERVAZIONE Prima di tutti intervento accertarsi che gli prodotto siano scollegati dall alimentazione di rete 6 1 Dopo l utiliz...

Page 18: ...Aspirador 7 Carcasa del motor 8 Empu adura 9 Interruptor principal de marcha paro ON OFF 10 Control de velocidad 11 Cable 12 Empu adura auxiliaria II CARACTER STICAS Descripci n Aspirador Soplador Ref...

Page 19: ...l producto o cuando no lo utilice Desconecte el suministro el ctrico si el producto el cable de alimentaci n o la extensi n sufren da os o cortes durante el funcionamiento Tire del enchufe para descon...

Page 20: ...s los servicios del producto excepto los indicados en la lista del Manual de instrucciones deben ser efectuados por personal de servicio competente 9 Aseg rese de apagar el motor antes de bajar el pro...

Page 21: ...e el conducto de conexi n del aparato hacia atr s del aparato Desenchufe inmediatamente el aparato si el cable de corriente o de extensi n est n da ados NO TOCAR AL CABLE ANTES DE TENERLO DESCONECTADO...

Page 22: ...ular el producto aseg rese de que est desconectado del suministro el ctrico 4 1 Desembalaje Saque el producto de su embalaje Compruebe que el producto y los accesorios no presenten da os 4 2 Contenido...

Page 23: ...como en la agricultura y la selvicultura 5 2 Utilizaci n 5 2 1 Funcionamiento Habr que asegurarse de que el soplador aspirador se haya conectado solamente a tomas de corriente convencional de 240 V de...

Page 24: ...habr que asegurarse de que la m quina se haya desconectado del suministro el ctrico Para vaciar la bolsa abrir el cierre de cremallera vaciar la bolsa y cerrar de nuevo la cremallera Mientras la bolsa...

Page 25: ...uardarse en un lugar seco bien ventilado cerrado fuera del alcance de los ni os 6 4 Eliminaci n Cuando decida deshacerse de la m quina aseg rese de seguir el reglamento local No desechar con o junto a...

Reviews: