V. OPERATION

 

 
5.1- Intended use 

- JET pump (alone or in a booster group) is designed to draw clear water. 
- It must be installed in a dry, ventilated place, protected from weather and excessive heat. 
- The maximum suction height should not exceed 8 meters. 
- Properly installed, your pump will operate with maximum efficiency and will give you complete 
satisfaction. 
- The pump is designed for routine household uses such as gardening, irrigation systems, increased water 
pressure distribution in non-food, pumping water tanks... 
- The pump must not be used for operations not described in this manual. 
 

It should not be used in particular for:

 

- pumping seawater, waste water, water containing solids, sand or abrasive particles in suspension,   
water containing corrosive substances in general. 
- pumping water having a temperature above 35°C. 
- pumping of explosive, flammable or dangerous liquids. 
- pumping water intended for human consumption or food liquids. 

NOTE: 

- This pump is not intended for cleaning and other pool maintenance operations. 
- The pump must not be used in outdoor fountains, garden ponds and similar places. 
- The pump is not designed for industrial and / or commercial applications (eg, in public parks, sports 
fields ...). 
 

Additional information for booster pump 

The booster optimizes the water supply by limiting repeated on/off, and especially allows maintaining a 
constant pressure in the system.

 

 

5.2- Operation 

- Proceed with the suction and discharge lines connections described in chapter 4 above. 
- Press the on / off switch (5). 
- The pump turns on when you open the terminal (e.g. water tap, spray gun...) 
 

Additional Information for booster pump

 

- The pump starts and stops automatically when the pressure in the vessel is approximately 3 bar. 
- Slowly open the discharge valve. The pump begins to discharge, without its engine running, through the 
water supply in the tank. 
- When the pressure in the tank drops below about 1.5 bar, the pump starts and remains on until the 
pressure of the tank reach about 3 bar. 
- To stop the pump cycles, slowly close the discharge valve. 
- Always follow these instructions to avoid creating excess pressure in the system and avoid "water 
hammer" effect. 
 

5.3- Advise for users 

IMPORTANT! 
- Do not operate the pump without water in the pump body: extended operation of the pump when the 
discharge valve is closed, can seriously damage the pump. 
- In case of power failure, it is best to unplug the power outlet. 
- In case of prolonged non-use, ensure to switch off the power. 

Summary of Contents for 512616

Page 1: ...tilisation EN GARDEN PUMPAND BOOSTER PUMP User and maintenance manual IT POMPA DI SUPERFICIE E POMPA SURJET CARENATA Manuale di istruzioni e di manutenzione R f Art Nr PRJETF130 512616 PRS20JETF130 51...

Page 2: ...entretien des piscines Ces pompes ne sont pas destin es pomper de l eau potable I NOMENCLATURE 1 Port d aspiration 2 Couvercle filtre 3 Port de refoulement 4 Poign e 5 Interrupteur 6 C ble lectrique...

Page 3: ...e l environnement de l aire de travail Garder l aire de travail bien clair e lumi re naturelle ou artificielle suffisante Garder l aire de travail bien ventil e Ne pas utiliser le produit s il y a ris...

Page 4: ...ion de rallonge Lorsque le produit est utilis avec une rallonge n utiliser que des rallonges con ues et pr vues pour supporter le courant alimentant le produit 16 Rester vigilant Surveiller ce que vou...

Page 5: ...ctement vers l appareil ou d autres composants lectriques Danger de mort par lectrocution 9 Placer la rallonge de telle mani re qu elle ne puisse entrer en contact avec un quelconque liquide 10 Ne pas...

Page 6: ...stall de mani re tre prot g contre les d bordements et contre les chutes Des exigences l gales nationales ou locales suppl mentaires peuvent exister et doivent tre observ es Lorsque vous utilisez le p...

Page 7: ...e haut Dans le cas de puits comportant du sable ou des gravillons mettre la cr pine 50cm du fond ou dans un seau au fond du puits Le tuyau d aspiration doit tre aussi court que possible car la capacit...

Page 8: ...st con ue pour aspirer des eaux claires Elle doit tre install e dans un lieu sec a r l abri des intemp ries et de la chaleur La hauteur maximum d aspiration ne doit pas d passer 8 m tres Correctement...

Page 9: ...et de refoulement est ferm peut endommager s rieusement la pompe En cas de panne de courant il est pr f rable de d brancher la fiche de prise de courant En cas d inutilisation prolong e de la pompe co...

Page 10: ...t Apporter le produit une d chetterie ou un centre de collecte des d chets des quipements lectriques et lectroniques ou renseignez vous aupr s de votre commune Effectuer la mise au rebut du produit de...

Page 11: ...ools This pump is not intended for pumping drinking water I PARTS LIST 1 Intake port 2 Filter cover 3 Output port 4 Handle 5 On Off switch 6 Power cord with plug 7 Air valve 8 Tank 9 Manometer 512616...

Page 12: ...ent Keep work area well lit natural light or sufficient artificial lighting Keep work area well ventilated Do not use product where there is risk to cause fire or explosion in the presence of flammabl...

Page 13: ...common sense Do not operate product when you are tired under the influence of alcohol prescription medicines or drugs 17 Check damaged parts Before further use or reuse of the product it should be car...

Page 14: ...ith the conveying medium 11 Do not leave the device unsupervised Unplug the mains plug during periods of extended absence 12 As a general rule repairs are only to be carried out by an electrician If r...

Page 15: ...ts due to improper installation This pump must be installed in accordance with local standards and by a qualified person we recommend you to contact an electrician The fixed pipeline that will connect...

Page 16: ...ine are an indication that there may be a leakage 4 5 Connecting the discharge line not supplied The discharge hose not supplied must have a minimum diameter of 25 mm and must be rigid and kink resist...

Page 17: ...industrial and or commercial applications eg in public parks sports fields Additional information for booster pump The booster optimizes the water supply by limiting repeated on off and especially al...

Page 18: ...detergents or abrasive sponges or sharp or pointed objects 6 2 Breakdown Never attempt to dismantle the pump If necessary have it checked and repaired by an authorized centre consult your dealer 6 3...

Page 19: ...pompa non prevista per il pompaggio dell acqua di consume I ELENCO COMPONENTI 1 Bocca di aspirazione 2 Copperchio con filtro e bocca di adescamento 3 Bocca di scarico 4 Maniglia 5 Interruttore 6 Cavo...

Page 20: ...Il disordine nell area di lavoro aumenta il rischio di incidenti 2 Tenere conto dei fattori circostanti di influenza Accertarsi che l illuminazione sia buona luce del sole o illuminazione artificiale...

Page 21: ...pportare la corrente che alimenta l attrezzo 16 Fare sempre attenzione Guardare quello che si fa Procedere con giudizio Non utilizzare l utensile se non si concentrati si stanchi o sotto l influenza d...

Page 22: ...avviare la macchina se persone o animali sono in acqua o in contatto con i tubi 11 Non lasciare incustodito l apparecchio Scollegare l alimentazione durante i periodi di non utilizzo o durante una lun...

Page 23: ...o collegato alla pompa deve includere un dispositivo di separazione avente contatti cui larghezza dell apertura almeno pari a 3 mm in tutti i poli Si consiglia di alimentare la pompa di un trasformato...

Page 24: ...essione della pompa Se il liquido contaminato un filtro di aspirazione deve essere usato per proteggere la pompa da sabbia e sporcizia IMPORTANTE Il tubo di aspirazione deve essere dotato di valvola d...

Page 25: ...ua per reti di distribuzione dell acqua non alimentate pompaggio di acqua da serbatoi e lavaggio a spruzzi La pompa non deve essere impiegata per usi non indicati nel presente manuale In particolare l...

Page 26: ...ompa deve essere accuratamentc vuotata o messa in condbioni fuori gelo Risciacquate periodicamente la pompa con acqua chiara compreso il circuito di aspirazione Evitare il pompaggio di liquidi che con...

Reviews: