background image

Page 

11

 / 

26

 

 

EN -

 Original instructions

 

I. Parts List 
II. Characteristics 

III. Safety instructions 
IV. Getting Started 

V. Operation 
VI. Maintenance and Storage 

 
 

WARNING

:   

Carefully read this instruction manual before operating this appliance.   
Incorrect operation may cause injury and/or damages. 

Please keep this manual for future reference. 
 

 

Warning: This pump is not intended for swimming pools.     
Under no circumstances should it be used for the cleaning or maintenance of swimming pools.   
This pump is not intended for pumping drinking water. 
 

 

I. PARTS LIST 

1- Intake port 
2- Filter cover 
3- Output port 
4- Handle 
5- On/Off switch 
6- Power cord with plug 
7- Air valve 
8- Tank 
9- Manometer 

 

 
 
 

512616 

 

517626 

 
II. CHARACTERISTICS 

 

Reference 

PRJETF130 / 512616 

PRS20JETF130 / 512626 

Model / Type 

JGP130022 

JGP130022C 

Voltage & frequency 

230V ~ 50Hz 

230V ~ 50Hz 

Power 

1300W 

1300W 

No load speed 

2850min

-1

 

2850min

-1

 

Protection level 

IP X4 

IP X4 

Max output capacity 

75 L/min 

75 L/min 

Max. pressure 

4.8 bar 

1.5 – 3.0 bar 

Max. delivery height 

48 m 

48 m 

Max. suction level 

8 m 

8 m 

Connector size 

1’’ (25mm) 

1’’ (25mm) 

Tank capacity 

19 L 

Liquid temperature (max.) 

35°C 

35°C 

Weight (kg) approx. 

10.5 kg 

16.3 kg 

 

Summary of Contents for 512616

Page 1: ...tilisation EN GARDEN PUMPAND BOOSTER PUMP User and maintenance manual IT POMPA DI SUPERFICIE E POMPA SURJET CARENATA Manuale di istruzioni e di manutenzione R f Art Nr PRJETF130 512616 PRS20JETF130 51...

Page 2: ...entretien des piscines Ces pompes ne sont pas destin es pomper de l eau potable I NOMENCLATURE 1 Port d aspiration 2 Couvercle filtre 3 Port de refoulement 4 Poign e 5 Interrupteur 6 C ble lectrique...

Page 3: ...e l environnement de l aire de travail Garder l aire de travail bien clair e lumi re naturelle ou artificielle suffisante Garder l aire de travail bien ventil e Ne pas utiliser le produit s il y a ris...

Page 4: ...ion de rallonge Lorsque le produit est utilis avec une rallonge n utiliser que des rallonges con ues et pr vues pour supporter le courant alimentant le produit 16 Rester vigilant Surveiller ce que vou...

Page 5: ...ctement vers l appareil ou d autres composants lectriques Danger de mort par lectrocution 9 Placer la rallonge de telle mani re qu elle ne puisse entrer en contact avec un quelconque liquide 10 Ne pas...

Page 6: ...stall de mani re tre prot g contre les d bordements et contre les chutes Des exigences l gales nationales ou locales suppl mentaires peuvent exister et doivent tre observ es Lorsque vous utilisez le p...

Page 7: ...e haut Dans le cas de puits comportant du sable ou des gravillons mettre la cr pine 50cm du fond ou dans un seau au fond du puits Le tuyau d aspiration doit tre aussi court que possible car la capacit...

Page 8: ...st con ue pour aspirer des eaux claires Elle doit tre install e dans un lieu sec a r l abri des intemp ries et de la chaleur La hauteur maximum d aspiration ne doit pas d passer 8 m tres Correctement...

Page 9: ...et de refoulement est ferm peut endommager s rieusement la pompe En cas de panne de courant il est pr f rable de d brancher la fiche de prise de courant En cas d inutilisation prolong e de la pompe co...

Page 10: ...t Apporter le produit une d chetterie ou un centre de collecte des d chets des quipements lectriques et lectroniques ou renseignez vous aupr s de votre commune Effectuer la mise au rebut du produit de...

Page 11: ...ools This pump is not intended for pumping drinking water I PARTS LIST 1 Intake port 2 Filter cover 3 Output port 4 Handle 5 On Off switch 6 Power cord with plug 7 Air valve 8 Tank 9 Manometer 512616...

Page 12: ...ent Keep work area well lit natural light or sufficient artificial lighting Keep work area well ventilated Do not use product where there is risk to cause fire or explosion in the presence of flammabl...

Page 13: ...common sense Do not operate product when you are tired under the influence of alcohol prescription medicines or drugs 17 Check damaged parts Before further use or reuse of the product it should be car...

Page 14: ...ith the conveying medium 11 Do not leave the device unsupervised Unplug the mains plug during periods of extended absence 12 As a general rule repairs are only to be carried out by an electrician If r...

Page 15: ...ts due to improper installation This pump must be installed in accordance with local standards and by a qualified person we recommend you to contact an electrician The fixed pipeline that will connect...

Page 16: ...ine are an indication that there may be a leakage 4 5 Connecting the discharge line not supplied The discharge hose not supplied must have a minimum diameter of 25 mm and must be rigid and kink resist...

Page 17: ...industrial and or commercial applications eg in public parks sports fields Additional information for booster pump The booster optimizes the water supply by limiting repeated on off and especially al...

Page 18: ...detergents or abrasive sponges or sharp or pointed objects 6 2 Breakdown Never attempt to dismantle the pump If necessary have it checked and repaired by an authorized centre consult your dealer 6 3...

Page 19: ...pompa non prevista per il pompaggio dell acqua di consume I ELENCO COMPONENTI 1 Bocca di aspirazione 2 Copperchio con filtro e bocca di adescamento 3 Bocca di scarico 4 Maniglia 5 Interruttore 6 Cavo...

Page 20: ...Il disordine nell area di lavoro aumenta il rischio di incidenti 2 Tenere conto dei fattori circostanti di influenza Accertarsi che l illuminazione sia buona luce del sole o illuminazione artificiale...

Page 21: ...pportare la corrente che alimenta l attrezzo 16 Fare sempre attenzione Guardare quello che si fa Procedere con giudizio Non utilizzare l utensile se non si concentrati si stanchi o sotto l influenza d...

Page 22: ...avviare la macchina se persone o animali sono in acqua o in contatto con i tubi 11 Non lasciare incustodito l apparecchio Scollegare l alimentazione durante i periodi di non utilizzo o durante una lun...

Page 23: ...o collegato alla pompa deve includere un dispositivo di separazione avente contatti cui larghezza dell apertura almeno pari a 3 mm in tutti i poli Si consiglia di alimentare la pompa di un trasformato...

Page 24: ...essione della pompa Se il liquido contaminato un filtro di aspirazione deve essere usato per proteggere la pompa da sabbia e sporcizia IMPORTANTE Il tubo di aspirazione deve essere dotato di valvola d...

Page 25: ...ua per reti di distribuzione dell acqua non alimentate pompaggio di acqua da serbatoi e lavaggio a spruzzi La pompa non deve essere impiegata per usi non indicati nel presente manuale In particolare l...

Page 26: ...ompa deve essere accuratamentc vuotata o messa in condbioni fuori gelo Risciacquate periodicamente la pompa con acqua chiara compreso il circuito di aspirazione Evitare il pompaggio di liquidi che con...

Reviews: