background image

Page 

15

 / 

26

 

 

IV. GETTING STARTED 
 

 

Before any intervention on product, ensure that product is disconnected from its power 
source. 

 

4.1- Unpacking 

- Remove product from its packaging. 
- Check that product and accessories are not damage   
 

4.2- Important recommendations 

Before connecting to the power source, you must observe the following: 
- The device must be placed on a horizontal, leveled surface that is sufficiently capable of supporting the 
total weight of the device when filled with water. 
- Make sure that the power supply corresponds with the connection specifications of the device (see rating 
label). 
- To prevent vibrations, the device should be placed on an elastic support (e. g. a rubber mat). 
- The installation site must be well ventilated and protected from the effects of weather. 
- When being used near garden ponds and swimming pools, the device must be set up so as to guard 
against overflowing and protected against falling in.   
- Additional legal requirements must be observed 
- When operating indoors you must ensure that there is a drain in the floor or a leak prevention 
mechanism. 
- Before starting up, check the suction hose to ensure that it is sealed. Bubbles of air in the suction hose 
are an indication that there may be leaks and may lead to failure of the device.   
 
WARNING! 
- The warranty does not cover accidents due to improper installation. This pump must be installed in 
accordance with local standards and by a qualified person (we recommend you to contact an electrician). 
- The fixed pipeline that will connect the pump must include a separation device having contacts with the 
opening distance of at least 3 mm in all poles. 
- It is recommended that the device be connected with a residual current of not more than 30 mA by means of a 
residual-current-operated protective device 
- The total head must not exceed 48 m. 
- The cable must be at least one cable H07 RN-F 3×1mm

2

 (or exceed 1mm

2

) (line, neutral and earth).. 

 

4.3- Electrical connection 

a) Make sure that the power supply corresponds with the connection specifications of the device (see 
rating label). 

b) Check that the power cable is not damaged. 
c) Connect plug to a wall socket 10/16A fitted with a ground connection. 
d) Turn the pump for 2 to 3 seconds to perform a dry run of the pump. 
Do not operate the pump without water for more than 2 to 3 seconds to avoid overheating. This will cause 
permanent damage. 
e) Disconnect the pump from the power supply (remove the plug from the wall socket), and then proceed 
with suction and delivery line connection, as described in the following paragraphs. 
f) Ensure that the electrical connection is protected against water splashing.

 

g) When operating outdoors, the electrical connections must be splash-proof; they must not lie in water. 
h) Extension cords must have sufficient wire cross section; cable drums must be complete unwound 
 

Summary of Contents for 512616

Page 1: ...tilisation EN GARDEN PUMPAND BOOSTER PUMP User and maintenance manual IT POMPA DI SUPERFICIE E POMPA SURJET CARENATA Manuale di istruzioni e di manutenzione R f Art Nr PRJETF130 512616 PRS20JETF130 51...

Page 2: ...entretien des piscines Ces pompes ne sont pas destin es pomper de l eau potable I NOMENCLATURE 1 Port d aspiration 2 Couvercle filtre 3 Port de refoulement 4 Poign e 5 Interrupteur 6 C ble lectrique...

Page 3: ...e l environnement de l aire de travail Garder l aire de travail bien clair e lumi re naturelle ou artificielle suffisante Garder l aire de travail bien ventil e Ne pas utiliser le produit s il y a ris...

Page 4: ...ion de rallonge Lorsque le produit est utilis avec une rallonge n utiliser que des rallonges con ues et pr vues pour supporter le courant alimentant le produit 16 Rester vigilant Surveiller ce que vou...

Page 5: ...ctement vers l appareil ou d autres composants lectriques Danger de mort par lectrocution 9 Placer la rallonge de telle mani re qu elle ne puisse entrer en contact avec un quelconque liquide 10 Ne pas...

Page 6: ...stall de mani re tre prot g contre les d bordements et contre les chutes Des exigences l gales nationales ou locales suppl mentaires peuvent exister et doivent tre observ es Lorsque vous utilisez le p...

Page 7: ...e haut Dans le cas de puits comportant du sable ou des gravillons mettre la cr pine 50cm du fond ou dans un seau au fond du puits Le tuyau d aspiration doit tre aussi court que possible car la capacit...

Page 8: ...st con ue pour aspirer des eaux claires Elle doit tre install e dans un lieu sec a r l abri des intemp ries et de la chaleur La hauteur maximum d aspiration ne doit pas d passer 8 m tres Correctement...

Page 9: ...et de refoulement est ferm peut endommager s rieusement la pompe En cas de panne de courant il est pr f rable de d brancher la fiche de prise de courant En cas d inutilisation prolong e de la pompe co...

Page 10: ...t Apporter le produit une d chetterie ou un centre de collecte des d chets des quipements lectriques et lectroniques ou renseignez vous aupr s de votre commune Effectuer la mise au rebut du produit de...

Page 11: ...ools This pump is not intended for pumping drinking water I PARTS LIST 1 Intake port 2 Filter cover 3 Output port 4 Handle 5 On Off switch 6 Power cord with plug 7 Air valve 8 Tank 9 Manometer 512616...

Page 12: ...ent Keep work area well lit natural light or sufficient artificial lighting Keep work area well ventilated Do not use product where there is risk to cause fire or explosion in the presence of flammabl...

Page 13: ...common sense Do not operate product when you are tired under the influence of alcohol prescription medicines or drugs 17 Check damaged parts Before further use or reuse of the product it should be car...

Page 14: ...ith the conveying medium 11 Do not leave the device unsupervised Unplug the mains plug during periods of extended absence 12 As a general rule repairs are only to be carried out by an electrician If r...

Page 15: ...ts due to improper installation This pump must be installed in accordance with local standards and by a qualified person we recommend you to contact an electrician The fixed pipeline that will connect...

Page 16: ...ine are an indication that there may be a leakage 4 5 Connecting the discharge line not supplied The discharge hose not supplied must have a minimum diameter of 25 mm and must be rigid and kink resist...

Page 17: ...industrial and or commercial applications eg in public parks sports fields Additional information for booster pump The booster optimizes the water supply by limiting repeated on off and especially al...

Page 18: ...detergents or abrasive sponges or sharp or pointed objects 6 2 Breakdown Never attempt to dismantle the pump If necessary have it checked and repaired by an authorized centre consult your dealer 6 3...

Page 19: ...pompa non prevista per il pompaggio dell acqua di consume I ELENCO COMPONENTI 1 Bocca di aspirazione 2 Copperchio con filtro e bocca di adescamento 3 Bocca di scarico 4 Maniglia 5 Interruttore 6 Cavo...

Page 20: ...Il disordine nell area di lavoro aumenta il rischio di incidenti 2 Tenere conto dei fattori circostanti di influenza Accertarsi che l illuminazione sia buona luce del sole o illuminazione artificiale...

Page 21: ...pportare la corrente che alimenta l attrezzo 16 Fare sempre attenzione Guardare quello che si fa Procedere con giudizio Non utilizzare l utensile se non si concentrati si stanchi o sotto l influenza d...

Page 22: ...avviare la macchina se persone o animali sono in acqua o in contatto con i tubi 11 Non lasciare incustodito l apparecchio Scollegare l alimentazione durante i periodi di non utilizzo o durante una lun...

Page 23: ...o collegato alla pompa deve includere un dispositivo di separazione avente contatti cui larghezza dell apertura almeno pari a 3 mm in tutti i poli Si consiglia di alimentare la pompa di un trasformato...

Page 24: ...essione della pompa Se il liquido contaminato un filtro di aspirazione deve essere usato per proteggere la pompa da sabbia e sporcizia IMPORTANTE Il tubo di aspirazione deve essere dotato di valvola d...

Page 25: ...ua per reti di distribuzione dell acqua non alimentate pompaggio di acqua da serbatoi e lavaggio a spruzzi La pompa non deve essere impiegata per usi non indicati nel presente manuale In particolare l...

Page 26: ...ompa deve essere accuratamentc vuotata o messa in condbioni fuori gelo Risciacquate periodicamente la pompa con acqua chiara compreso il circuito di aspirazione Evitare il pompaggio di liquidi che con...

Reviews: