INsTALLATION sUPEr 4000
G
B
16
16
3
C
HECKING BEfOrE THE INsTALLATION
!! THE GATE sHALL MOVE frICTIONLEss !!
N.B.:
gate features must be uniformed with the standards and laws in
force. The door/gate can be automated only if it is in a good condition
and its conditions comply with the EN 12604 norm.
- The door/gate leaf does not have to have a pedestrian opening. in
the opposite case it is necessary to take the appropriate steps, in
accordance with EN 12453 norm (for instance; by preventing the
operation of the motor when the pedestrian opening is opened, by
installing a safety microswitch connected with the control panel).
- besides the electrical or mechanical limit switches available on the
operators, there must be, on both ends of the installation, a fixed
mechanical stopper which stop the gate in the unlikely event of ill
functioning of limit swithces on the operators. for this reason the fixed
mechanical stopper must be of an adeguate size to withstand the static
and kinetic forces generated by the gate (12) (fig.2).The guide must
be provided with two mechanical stops at its ends (12) (fig. 2).
- gate columns shall have anti-derailment guides on their top (fig. 3),
to avoid the unintentional gate release.
N.B.:
Eliminate those mechanical stops of the kind described by figure
3.
No mechanical stop shall be on top of the gate, since mechanical stops
are not safe enough.
M
OTOr AND rACK INsTALLATION
The base of the ratiomotor is equipped with 4 anchors so that it can be
cemented to the ground.
The rack must be fixed at a certain height with respect to the motor
base.
This height can be varied thanks to the slots on the rack.
The rack must not be welded, but simply fixed to the gate with threaded
screws.
The height needs to be adjusted so that the gate does not rest on the
reduction unit
traction gear (fig. 4, 5).
Holes with a diameter of 7 mm should be made to fix the rack into the
gate, and they
should be threaded using a M8 type screw tap.
The pinion must have a clearance of 1 to 2 mm with respect to the
rack.
2
5
4
Misure in mm
COMMAND TYPE
USE OF THE SHUTTER
Skilled persons
Skilled persons
Unrestricted use
(out of public area*)
(public area)
with manned operation
A
B
non possibile
with visible impulses
C or E
C or E
C and D, or E
(e.g. sensor)
with not visible impulses
C or E
C and D, or E
C and D, or E
(e.g. remote controldevice)
automatic
C and D, or E
C and D, or E
C and D, or E
* a typical example are those shutters which do not have access to any public way.
A: Command button with manned operation (that is, operating as long as activated),
like code ACG2013.
B: Key selector with manned operation, like code ACG1053.
C: Adjustable power of the motor.
D: Safety edges, like code ACG3015 and/or other safety devices to keep thrust force
within the limits of EN12453 regulation - Appendix A.
E: Photocells, like code ACG8026 (To apply every 60÷70 cm for all the height of the
column of the gate up to a maximum of 2,5 m - EN 12445 point 7.3.2.1).
Parts to install meeting the EN 12453 standard