35
TABLE SUMMARISING ALARMS AND VISUAL AND SOUND SIGNALS
SIGNALS DURING PROGRAMMING SEQUENCE
EVENT
BUZZER STATUS
FLASHER STATUS
PROGRAMMING LED DL1 STATUS
DIP 1 ON (HOLD MODE)
OR FAILURE OF A SAFETY DEVICE (ON
STEADY MODE)
OFF
OFF
FLASHES ON-OFF 250 MS
DIP 2 ON (FULL STROKE PROGRAMMING)
OFF
OFF
FLASHES ON-OFF 500 MS
DIP 2>1 ON (PEDESTRIAN STROKE
PROGRAMMING)
OFF
OFF
FLASHES ON-OFF 500 MS
PROGRAMMING SEQUENCE STOPPED DUE
TO INTERVENTION OF A SAFETY DEVICE
OFF
OFF
ON STEADY
EVENT
BUZZER STATUS
FLASHER STATUS
TWO-COLOUR DL10 LED STATUS (FOR REMOTE
CONTROL PROG.)
NO REMOTE CONTROL CODE ENTERED
OFF
OFF
FLASHES INTERMITTENTLY RED/GREEN
DIP 1 > 2 - FULL OPENING REMOTE
CONTROL CODE PROGRAMMING
OFF
OFF
FLASHES RED FOR 10 SECONDS
DIP 1 > 3 - PEDESTRIAN OPENING REMOTE
CONTROL CODE PROGRAMMING
OFF
OFF
FLASHES GREEN FOR 10 SECONDS
FULL OPENING REMOTE CONTROL CODE
PROGRAMMING, OUTCOME OK
1 TONE
OFF
TURNS GREEN ONCE
PEDESTRIAN OPENING REMOTE CONTROL
CODE PROGRAMMING, OUTCOME OK
1 TONE
OFF
TURNS RED ONCE
REMOTE CONTROL CODE NOT PRESENT IN
MEMORY
OFF
OFF
RED FLASH
MEMORY SATURATED BY REMOTE CONTROL
CODES (1000 CODES SAVED)
OFF
OFF
RUNS 6 GREEN FLASHES
FULL OPENING CODE DELETION
2 TONES
OFF
RUNS 2 RED FLASHES
PEDESTRIAN OPENING CODE DELETION
2 TONES
OFF
RUNS 2 GREEN FLASHES
WARNING SIGNALS DURING OPERATION
EVENT
BUZZER STATUS
FLASHER STATUS
LED STATUS AND SIGNAL OUTPUT
STOP BUTTON PRESSED
OFF
OFF
LED DL12 TURNS OFF
PHOTOCELL INTERVENTION
1 TONE
OFF
LED DL13 TURNS OFF
EDGE INTERVENTION
2 TONES
OFF
LED DL14 TURNS OFF
INTERVENTION OF CURRENT SENSOR
3 TONES
OFF
NO LED COMBINED
FAILURE OF A SAFETY DEVICE OR SAFETY
DEVICE ENGAGED FOR TOO LONG
OFF
OFF
LED DL1 FLASHES ON-OFF 250 MS
RUNNING WITH EMERGENCY BATTERIES
(24 Vdc)
OFF
CURRENTLY ENABLED
SIGNAL OUTPUT FLASHES ON-OFF TWICE FOR
250 MS FOLLOWED BY A PAUSE OF 2 SECONDS
EMERGENCY BATTERIES LOW SIGNAL
1 TONE EVERY 5 SECONDS FOR 1 MINUTE
(RESET BY ACTIVATING A CONTROL)
OFF
SIGNAL OUTPUT FLASHES CONTINUOUSLY ON-
OFF FOR 500 MS
ALARM FROM EDGE
2 TONES EVERY 5 SECONDS FOR 1 MINUTE
(RESET BY ACTIVATING A CONTROL)
ENABLED FOR 1 MINUTE (FLASHING) NO LED COMBINED
CURRENT SENSOR ALARM
3 TONES EVERY 5 SECONDS FOR 1 MINUTE
(RESET BY ACTIVATING A CONTROL)
ENABLED FOR 1 MINUTE (FLASHING) NO LED COMBINED
FAILED AUTO-TEST ALARM
4 TONES EVERY 5 SECONDS FOR 1 MINUTE
(RESET BY ACTIVATING A CONTROL)
OFF
NO LED COMBINED
ENCODER FAILURE ALARM
5 TONES EVERY 5 SECONDS FOR 1 MINUTE
(RESET BY ACTIVATING A CONTROL)
OFF
LED DL2 OFF
MEMORY NOT INSERTED ALARM
3 SECONDS ON - 3 SECONDS OFF
TURNS OFF ONLY WHEN THE MEMORY IS
INSERTED
OFF
NO LED COMBINED
INCORRECT SELF-DIAGNOSTIC ALARM
CONTINUOUS TONE FOR 10 SECONDS WITH
A PAUSE OF 2 SECONDS OFF
TURNS OFF ONLY IF DIP 2 IS SET TO OFF
OFF
LED DL1 ON STEADY
FUNCTIONAL BLOCK
OFF
OFF
TWO-TONE LED DL10 IS ON STEADY (ORANGE).