A - CONTROL PANEL FEATURES
G
B
J1
N F
Power supply 230 Vac 50/60 Hz - external to the control
panel - (120 V 60 Hz upon request)
J2
A+TEST
+ 24Vdc photocells self-test power supply
A-
- 24Vdc accessories power supply
A+ COM
+ 24Vdc accessories power supply
J3
COM A+
Common contacts / Positive 24 Vdc
B.I.O.
Contact (NO) dedicated to a clock
PED.
Pedestrian opening contact (NO)
START
Single pulse contact (NO)
CLOSE
Closing impulse contact (NO)
OPEN
Opening impulse contact (NO)
J4
COM A+
Common contacts / Positive 24 Vdc
STOP
STOP impulse contact (NC)
PHOTO 1
Photocells contact 1 (NC)
PHOTO 2
Photocells contact 2 (NC)
EDGE 1
Edge 1 contact (NC)
EDGE 2
Edge 2 contact (NC)
J5
Radio Antenna 433MHz
R-AUX
Auxiliary relay contact (NO) Max 700 W
SIGNAL -
Gate open state and battery state output indicator (24 Vdc 3
W max)
LOCK -
Electric lock connection (MAX 15W 12V)
24Vdc blinker (code ACG7061) power supply. Pay attention
to the polarity.
COM A+
Common contacts / Positive 24 Vdc
J6
RADIO
Connector for radio module ACG8069
J7
RADIO
Connector for radio receiver RIB, 24 Vdc supply
J8
BATTERY
CHARGER (24 V
DC SOLAR)
Connector for charge card of 24 Vdc battery (code ACG4773)
J9
SERIAL COM /
SYNC
Connector for serial connection
J10
APP+
Connector for APP+ card
J11
APP
Connector for APP Card
J12
RS485 termination of J10
J13
MOTOR 2
MOTOR 2 CONNECTION (without polarity)
J14
MOTOR 1
MOTOR 1 CONNECTION (without polarity)
J15
SECONDARY
TRANSFORMER
Connection to secondary coil of transformer 18 Vac
SENS
Trimmer for adjusting sensitivity to impact against an obstacle
TCA
Trimmer for automatic closing time adjustment (DISABLED
DEFAULT AND DL11 LED OFF)
RUN
Trimmer for high speed adjustment operations
LOW SP
Trimmer for low speed adjustment operations
PROG
Programming button
F1
T 2 A
Transformer protection fuse (external to the card B2 24V)
F2
T 8 A
Motors protection fuse
F
N
J15
F1
F2
J14
J13
J12 J11 J10
J9
J8
J7
J6
J1
J4
J3
J2
PROG
RUN
TCA
SENS
LOW SP
J5