RHODE UVC 2020.02.01
Page7
Attention:
The set includes dowels for fixing in walls made of building ceramics, in the case of other walls, e.g.
plasterboard or wooden panels, it is necessary to use specialized fixings.
Screw the wall brackets (3) to the wall or ceiling.
Attach the RHODE UV-C sterilizer to the wall holders (3) with the fixing screws (4).
Adjust the angle of the UV-C sterilizer to the wall or ceiling optimally and tighten the screws (4) securely.
Do not cover or block the sterilizer inlet or outlet.
Before connecting the device to the power supply, make sure that the voltage present in it is correct, i.e.
230V / 50Hz. If it is correct, insert the plug into a socket.
The device is ready for use.
9.3 BASE/STANDFOOT MOUNTING
Using the optional tripod or base, the RHODE UV-C sterilizer can be used as a standing device.
A standfoot or base is an accessory and is not included in the basic set.
Assemble the standfoot according to the diagram shown in the overview drawing point 7.
Screw the tripod screw (12) into place on the side of the RHODE UVC sterilizer housing.
Mount the wheels by pushing them all the way into the seats of the standfoot’s base.
Place the standfoot screw with the assembled sterilizer in the central socket of the standfoot's base.
Do not cover or block the sterilizer inlet or outlet.
Before connecting the device to the power supply, make sure that the voltage present in it is correct, i.e.
230V / 50Hz. If it is correct, insert the plug into a power socket.
The device is ready for use.
10. OPERATION
10.1 GENERAL REMARKS
The sterilizer is started up using the power switch (10) by supplying power..
After turning the power on, the fan starts and the UV-C radiators light up.
Air is sterilized continuously.
The sterilizer is equipped with air filters, the cleanliness of which should be periodically checked and, in the
event of significant pollution, replaced with new ones.
RHODE UV-C sterilizers can be additionally equipped with timers to control the working time of UV-C
radiators and to program work in daily and weekly modes. Timers are additional equipment and are not
included in the scope of delivery of the RHODE UV-C sterilizer in the basicoption.
10.2 REMOTE CONTROL NAVIGATION
The remotecontrolenableswireless on and off of the sterilizer and independent control of internal and
external UV-C radiators.
To activate the remotecontrolproceed as follows:
Start the sterilizer with the powerswitch (10), the internal and externalradiators of the sterilizerwillswitch on.
Switch off the sterilizerremotelyusing the
OFF
button on the remotecontrol.
Button
A
turns on internal UV-C radiators. Press again to turnit off.
Button
B
turns on external UV-C radiators. Press again to turnit off.
The
ON
buttonturns on bothinternal and external UV-C radiatorssimultaneously.
The
OFF
buttonsimultaneouslydeactivatesbothinternal and external UV-C radiators.
11. MAINTENANCE
11.1 GENERAL REMARKS
Before cleaning and maintenance work, make sure to switch off the sterilizer with the power switch (10) and
disconnect the plug from the socket.
Periodically clean the casing of the RHODE UV-C sterilizer from the outside using a cloth moistened with
soapy water, before removing the plug from the socket.
11.2 UV-C RADIATORS REPLACEMENT
INTERNAL RADIATORS
Remove the screws securing the rear cover (2) from the housing (1).
Remove the radiators from the catches and disconnect their two-pin shafts from electrical holders.