RHODE UVC 2020.02.01
Page6
8. ADDITIONAL EQUIPMENT (not covered by the standard set)
RHODE timer functions
BASIC
PROFI
Working hour counter
No
Yes
Radiator replacement indicator
No
Yes
Filter replacement sound indicator
No
Yes
External and internal timer
No
Yes
Day and week timer
No
No
Hour timer
Yes
Yes
Day Stage Quantity
1
1
8.1 INDUCTION WORKING HOUR COUNTER
-electromechanical hour meter is used to measure the operating time in hours of UV-C radiators.
8.2 MICROPROCESSOR WORKING HOUR COUNTER
- electronic counter for hours of operation of UV radiators with a 4-digit LCD display with indications with an
accuracy of 1 hour, with an acoustic notification of the obligation to replace the radiators.
8.3 BASIC TIMER
-
digital counter with a microprocessor, allows you to program the daily working time individually for each day
of the week.
8.4 PROFI TIMER
-
cyfrowy
programator łączy w sobie funkcje licznika godzin pracy i ustawienia czasu w jakim lampa ma
pracować.
8.5 REMOTE CONTROL
- enables remote on and off of the sterilizer.
8.6 PROFI BASE
- enables placing the RHODE UV-C sterilizer in a vertical position.
8.7 PROFI STANDFOOT
- enables placing the RHODE UV-C sterilizer in a vertical position. The base with soft wheels facilitates
comfortable and safe sliding of the device on the floor.
9. INSTALLATION
9.1 DELIVERY QUALITY
After removing the device from the packaging, check that the set is complete and that there are no external
damages that may have occurred during transport.
If you notice any damage, please contact your dealer.
After unpacking and before starting, leave the sterilizer at room temperature for about 30 minutes to equalize
the temperature of the device with the temperature of the room in which it will be installed.
New UV-C radiators in the first phase of their work can emit a minimal amount of ozone, causing a
characteristic smell in the room. It is recommended to pre-heat the radiators for approx. 100 hours
without people being in the room during this time.
9.2 WALL/CEILING MOUNTING
The device should be installed in a convenient place ensuring optimal air circulation in the room and allowing
easy access for maintenance, away from sources of heat, vibration and moisture.
Make sure the wall or ceiling on which you mount the device is stable enough!
Using a template, mark the fixing holes on the wall surface with a pencil.
Drill 4 holes in the wall with a Ø 8 mm drill bit to a depth enabling proper seating of the wall plugs.