RHODE UVC 2020.02.01
Page3
1. MANUFACTURE`S NOTE
Thank you for purchasing the RHODE-UVC air decontamination device. To guarantee long and trouble-free
operation of the device, please read this manual carefully and follow the instructions contained therein.
With a view to further improving the technical and utility values, in the interests of continuous improvement of the
quality of its products, RHODE reserves the right, without prior notification, to make appropriate modifications to the
device without prejudice to basic technical data.
RHODE is not responsible for material or human damage resulting from incorrect operation of the device, incorrect
connections or incorrect installation, and maintenance - not in accordance with the instructions.
Thank you for trusting in our brand and we wish you much satisfaction from the operation of the purchased device.
If you have any questions or problems arising from the use of the purchased device, please contact our Technical
Department.
2. DESCRIPTION AND PROPERTIES OF THE MACHINE
RHODE-UVC sterilizers are designed for the decontamination of rooms based on the use of UV-C ultraviolet
radiation. RHODE UV-C single-function flow devices are based on an internal ventilation system. The air sucked into
the sterilizer chamber passes through the filter located close to the inlet. Here, larger particles are blocked to prevent
contamination of the germicidal lamp reflectors. Then the air is passed directly through a low-pressure mercury lamp,
which, thanks to UV-C rays with a precisely emitted wave length of 253.7 nm, destroys all microorganisms.
Returning disinfected and purified air is released through the end nozzle, which completes the process of effective
cleaning.
The design of the single-function sterilizer does not cause a threat to people staying in the room during
operation.
The dual function sterilizer allows the use of independent room lighting by switching on external UV-C
radiators. In such a situation it is forbidden for people and animals to stay in the sterilized room
.
The device guarantees continuous air sterilization with a capacity of up to 60 m³ / h.
This device can be used only inside buildings, in the temperature range from 5 to 40 ° C [41 to 104 ° F] and humidity
25 to 75%.
A voltage tolerance of up to 10% of the nominal value is allowed.
3. SAFETY INFORMATION
3.1 HEALTH AND SAFETY INFORMATION
The RHODE UV-C sterilizer is a potentially dangerous electrical device.
To avoid electric shock, the device requires connection to an electrical system equipped with a protective
grounding plug.
The power plug must be easily accessible.
Secure the power cord against accidental damage.
A damaged cable should be replaced immediately with another one provided by the supplier.
Do not shorten or extend the power cord yourself.
The device may only be supplied with electricity which is in accordance with the information on the type plate
All electrical connections should be checked before operation. Damaged connections prevent working with
the device.
The device is only used for dry sterilization of indoor air.
It is forbidden to turn on the lamp power supply with the housing removed.
Switching on UV-C lamps may damage your eyesight!
Before starting maintenance work, disconnect the device from the power supply.
ATTENTION
UV-C radiation is harmful to the eyes and skin!
The radiators should not be switched on in open fittings when people or animals are nearby!