background image

Important Notes for Installers:

 

 

PROGRAMMING REMOTE CONTROLS:

PROGRAMMING REMOTE CONTROLS:

  

 
If you find that only one remote control is working, check that you have followed this procedure:  
To program, disconnect all power to alarm (i.e. remove fuse 

&

 backup battery). After 10 seconds replace the fuse. 

Press Button 1 on the first remote control. A  single confirmation chirp should be heard. If you intend to use the second 
remote control, press Button 1 on this remote within 5 seconds of the first remotes confirmation chirp. Another single 
chirp will be given to confirm that this remote is also learnt into the alarm. Now install the backup battery. 

Note: Whenever power is lost to the alarm, i.e. both the backup battery & the car battery are disconnected, 
this procedure must be repeated, as remote codes are not retained in memory. This will enable you to de lete 
a remote in case it is lost or stolen.  

  

CENTRAL LOCKING CONNECTION:

CENTRAL LOCKING CONNECTION:   

 

The Rhino Accel Plus does not provide dedicated central locking output wires i.e. separate lock & unlock pulses. 
Instead, the negative on arm wire from the Accel Plus can be utilised to activate our after-market central locking kit, 
provided the following simple modification is made to the central locking control module.  
 
If you already have existing factory fitted central locking in your vehicle, you will require an additional part – 
DLKACCEL. Contact your dealer for further information. 
 

Parts required: 
 

1 x 2k2

 Resistor (Red,Red,Red,Gold)   

 

Procedure: 
 

Remove the printed circuit board from the control module. This is achieved by gently prising out the surround around 
the connector block & sliding out the PCB. The modification is carried out on the back of the board. 

 

 

Solder a wire link 

between these two 

square pads 

 Solder the resistor 
between these two 

round  pads.  

Connect 

ORANGE

 wire 

from Accel Plus to 

PIN 8

 

on control module. 

Reviews: