![RHINO 50F Manual Download Page 7](http://html.mh-extra.com/html/rhino/50f/50f_manual_1452406007.webp)
2. Operation instructions:
a) In the Cooling models:
Ta
≥
Ts+1˚C (1˚F), the cooling starting.
Ta
≤
Ts-1˚C (1˚F), the compressor stops and only the fan motor remains working
at the set fan speed.
Ta: Room Surrounding Temperature
Ts: Setting Temperature
Sleep mode, pressing Timer and Down button can set the sleep function. In sleep function,
after operating two hours, the set temperature increases 1˚C (1˚F) automatically. After
operating for another 2 hours, the set temperature will increase 1˚C (1˚F) again. Then, the set
temperature will not change and the fan is forced to switch to low level.
b) In the dry mode, if the ambient temperature
≥
17˚C (62˚F), the compressor will start. Then,
the unit is controlled in the following manner: when the ambient temperature
≤
15˚C (59˚F),
the compressor shuts down. When the ambient temperature rises to be
≥
17˚C (62˚F), the
compressor starts again. The start/stop of the compressor meets the requirement for
3-minute protection time.
3. Timer setting
a) Press the Timer button to enter timed shutdown. The timer indicator will illuminate.
b) Press the Timer button to enter the timing function (timed start/timed shutdown). Adjust
the time using the up or down button to set the time. The time will cycle in the order of
1 - 2 - 3 -……24- 0 - 1 hours or 24 - 23 - 22 -……1- 0 - 24 hours. The adjustment time of
the timing function is relative time.
c) After timed start is set and start time is reached, the unit will start. The timer display
indicator will be replaced by the ambient temperature.
d) After timed shutdown is set, once the timed shutdown time is reached, the unit will shut
down. Once set the timer indicator will extinguish and the ambient temperature is displayed.
e) Only the last setting of the timing function is valid and valid once only.
f) ON/OFF operations caused by the button or remote control will clear all timing settings.
g) Once the timing is determined, if the timer button is pressed once, it is possible to query the
remaining timed start/shutdown time. If the timer button is pressed twice continuously
within 5s, it is possible to cancel timing.
4. Operation instructions of the remote control
The operation instructions of the buttons of this simple remote control are as follows:
a) Power button: press this button to turn on/off the unit;
b) Timer button: upon shutdown, press this button to set timed start; upon start, press this
button to set timed shutdown.
c) High button: press this button to allow the unit to operate in the high fan speed state(except
in the dry and sleep modes);
d) Low button: press this button to allow this unit to operate in the low fan speed state;
e) Up button: press this button to increase the temperature and timing value;
f) Down button: press this button to decrease the temperature and timing value;
g) ˚C -˚F button: press this button to switch between the degree Celsius and
degree Fahrenheit;
h) Cool button: press this button to set this unit to operate in the cooling mode;
i) Fan button: press this button to set this unit to operate in the air supply mode;
j) Dry button: press this button to set this unit to operate in the dehumidifying mode;
k) Sleep mode: press this button to set this unit to operate in the sleep mode.