Figure 3

Position of lower
air duct bottom step

Figure 4

Lower air duct
bottom joint

b) 

Rotate the exhaust clip  counter-clockwise until the clip locks firmly into position as shown 

below (as shown in Figure 2).

   

Do not rotate exhaust clip if not correctly aligned as this may damage the interlocking 

components.

c)

 

Installation of the exhaust hose assembly to the unit

Pull the end of the exhaust hose apart to allow easy access to the exhaust connector ;
Hold the exhaust clip clear of the duct opener. Align the exhaust connector to the opening on the 
rear of the unit. Push the exhaust clip down to lock the hose in position(as shown in Figure 3).

   

The end of the exhaust hose must be secured on the bottom stop of the outlet. (as 

shown in Figure 4).

Hold the unit with one hand and the heat exhaust hose short connector with other hand; or 
get help and one person hold the unit and the other person pulls the heat exhaust hose gently.
 
   

Do not separate the heat exhaust hose assembly from the unit. Do not tilt the unit when 

pulling apart the heat exhaust hose.

d)

 Installation of the window sealing board assembly

Half open the window and mount the window sealing board assembly onto the window,
either vertically or horizontally (as shown in Figure 5 and 6). Pull apart the parts of the window 
sealing board assembly, adjust the distance of the window sealing board assembly pulled apart so 
that the two ends of the assembly come into contact with the window frame, and fasten the parts 
of the assembly with copper screws.

Note

Note

Note

Summary of Contents for 50F

Page 1: ...it slightly by hand to avoid damage of the Louvre Keep the unit in an upright position when moving or repositioning Keep this unit away from petrol flammable gases or other heat sources Do not dismantle inspect or modify the unit without authorisation as this may impair the unit cause personal injuries or property damage to avoid dangers if the unit is faulty be sure to have it repaired by the man...

Page 2: ...nvenient storage pocket is located on the right of the handle at the back of the unit The rear of the unit includes a universal plug holder for convenient and safe storage of the cable and plug The position of the duct connector is high to allow for convenient assembly and smooth air flow Timed start shutdown function unique start shutdown music 3 minute delay compressor restart protection functio...

Page 3: ...ont shell 22 Base plate 10 Handle position right side remote 23 Remote control control storage area 24 circular connector 11 Back shell 25 Heat exhaust hose 12 C shape buckle for the heat 26 Heat exhaust hose short connector exhaust hose snap 27 Window sealing board assembly 13 Power cord INSTALLATION ADJUSTMENT 1 Installation WARNING leave this mobile air conditioner in an upright position for at...

Page 4: ...haust hose must be secured on the bottom stop of the outlet as shown in Figure 4 Hold the unit with one hand and the heat exhaust hose short connector with other hand or get help and one person hold the unit and the other person pulls the heat exhaust hose gently Do not separate the heat exhaust hose assembly from the unit Do not tilt the unit when pulling apart the heat exhaust hose d Installatio...

Page 5: ...ll be free from significant kinks greater than 45 The exhaust hose is 280mm 1000mm long Do not extend the hose or replace with other different hoses as this may affect the functions of the air conditioner The exhaust must be kink and blockage free note the air conditioner may overheat if the exhaust is obstructed Figure 7 Figure 8 Figure 9 Note ...

Page 6: ...b Mode Key Set the Cooling Dehumidifying and Fan Mode when unit is working or Timer On Situation c Fan Speed Press the button to scroll between the speed settings but not available in dehumidifying mode d Timer Key Set the Timer Off function when setting the time the regular time indicator will illuminate adjust the time while the regular time indicator is illuminated the room temperature will dis...

Page 7: ...e d After timed shutdown is set once the timed shutdown time is reached the unit will shut down Once set the timer indicator will extinguish and the ambient temperature is displayed e Only the last setting of the timing function is valid and valid once only f ON OFF operations caused by the button or remote control will clear all timing settings g Once the timing is determined if the timer button ...

Page 8: ...unit offers restart protection for the compressor Except that the compressor may start immediately when the unit is energized for the first time there is 3 minute delay start protection after the compressor is shut down REMOTE CONTROL Buttons of the remote control operating instructions as below 1 High Press this button to select high fan speed except dehumidifying mode and sleep mode 2 Low Press ...

Page 9: ...ly backward when draining Once the water is fully drained insert the water plug and screw on the water cap tightly Turn on the unit only after the water plug and drain cap are installed 2 Continuous drain a Screw off the water cap in the direction shown by the arrow and unplug the water plug Figure 11 b Insert a OD 13mm PVC drain hose 8mm 10mm into the water outlet Figure 12 c Connect the drain ho...

Page 10: ...direction shown by the arrow as shown in Figure 13 and 14 Note When taking out the filter frame or filter mesh the force shall be applied evenly to avoid twisting or damage of the filter frame or filter mesh Be sure to take out the filter frame first and then take out the filter mesh b Clean the filters in warm water about 40 C add a neutral cleaner and then dry as shown in Figure 15 3 Installatio...

Page 11: ...e top of the air outlet of the front shell with one hand and the handle position at the top of the back shell with another hand ensure the unit remains in the upright position As shown in Figure 17 a Do not handle the unit using the horizontal louvre b Keep upright when moving c Drain before moving Air outlet Handle position Figure 17 Note ...

Page 12: ... have no electricity Pipe temperature sensor failure Room temperature sensor failure Anti freeze protection The water in the baseplate of the unit reaches the full water level Connect the unit to a live socket and turn it on Drain the water stored in the unit It is recommended that this unit be operated at 10 35 C Change the set temperature Move unit into shaded area Close the door and window and ...

Reviews: