RHEINTACHO RT STROBE pocketLED  LASER Operating Instructions Manual Download Page 7

7.2 Display

 

 

Note

Preset values are retained in each mode (standard or pro 

selection)!

7.2.1 Overview of adjustable parameters

 

 

Note

Backlight changes depending on selected mode.

 

 

STROBO mode:

 white 

  TACHO mode: 

orange 

  Laser mode:

 light-blue

When inactive, the backlight turns off automatically after approx. 

10 seconds.

7.2.2 Standard selection (Figure 2 on page 2)

 

 

Note

Not all of the settings shown in figure 2 are available in standard 

selection.

7

Operating instructions 

RT STROBE pocketLED LASER

Set frequency

Select mode

Statistics

Set brightness 

Set phase shift

Select trigger

Select frequency unit

Select brightness unit

Set delay

Set trigger divider

Set slow motion

Set trigger signal edge

Store parameter 

Read parameter

Display

1/min / Hz / FPM

STROBO / TACHO

min / max / average

BRIGHT deg

PHASE deg

INT / EXT

1/min / Hz / FPM

BRIGHT deg / µs

DELAY ms

DIV.

SLOW

TRIG.

MEM in

MEM out

Standard

• 

• 

Without

Trigger

• 

• 

• 

Pro

 

• 

With

Trigger

 

• 

TACHO

 

STROBO

Device

Set 

value

• 

• 

• 

Select

parameter

Functions of button Menu “M” (B)

No.

(7)

No.

(7)

  

Off 
Display 

resp. setting the

frequency

  

Mode   

Display

-

Display

Adjustable 

parameters

Adjustable 

parameters

TACHO / STROBO

Description

Device is switched off.
Display resp. setting the

frequency frequency in 1/m, 

Hz or FPM. 
Change the frequency by 

pressing the buttons “PLUS” 

(E  ),  “MINUS”  (D),  “DIV”  (F)                                                                                        

and/or “MUL” (G).

Description

Selection of the mode: 

TACHO or STROBO

How to set the frequency:

1.  Switch on the device by pressing the button “ON / OFF” (A) for at least 1 second.

  → The following will then appear in the display for a few seconds

    ▪  all settings followed by

    ▪  “S”,  for standard selection

  → The following will then appear in the display:

       

2. Set the desired frequency by pressing the

        

buttons “PLUS” (E ), “MINUS” (D), “DIV” (F)

        

and/or “MUL” (G).

     

þ

 This setting is now active.

How to select the mode:

1.  Switch on the device by pressing the button “ON / OFF” (A) for at 

  least 1 second.

  → The following will then appear in the display for a few seconds

    ▪  all settings followed by

    ▪  “S”,  for standard selection

    → The following will then appear in the display:

2. Press the button Menu “M” (B) to switch 

between the different settings  and operation 

modes in the sequence of the display indica-

tor. Select the parameter you want to change 

(e.g. STROBO/TACHO).

    

    → The following will appear in the display:

    → The active parameter flashes 

3.  Switch between the parameters by pressing the buttons “MINUS” (D) or 

  “PLUS” (E).

4.  Press the button menu “M” (B) again to move to the next parameter.

þ

 This setting is now active.

Summary of Contents for RT STROBE pocketLED LASER

Page 1: ...RHEINTACHO TUTORIAL Operating instructions RT STROBE pocketLED LASER Multifunction device with LED Stroboscope Laser Tachometer RHEINTACHO TUTORIAL...

Page 2: ...er divider DIV 9 Slow motion SLOW 10 Trigger signal edge TRIG 11 Internal external trigger INT EXT 12 Store read parameter MEMORY IN MEMORY OUT 13 Statistics average min max 14 Pro selection P 15 Batt...

Page 3: ...operating instructions for the version with trigger connection 6 7 Operation 6 7 1 Button assignment 6 7 2 Display 7 7 2 1 Overview of adjustable parameters 7 7 2 2 Standard selection 7 7 2 3 Pro sele...

Page 4: ...x AA size disposable batteries or 3 x NiMH rechargeable batteries Continuous use time 5h 6 000 FPM Housing Material Aluminium ABS Heavy duty design Dimensions device 191 x 82 x 60 mm Dimensions case 2...

Page 5: ...arning Risk of injury Moving objects appear still or in slow motion in stroboscopic light Do not touch such objects under any circumstance Warning Risk of injury The device may not be used in potentia...

Page 6: ...ually switched between external and internal trigger signals see section 7 2 2 Standard selection How to select an internal external trigger 7 Operation Note Please note that this device comes in two...

Page 7: ...O STROBO Description Device is switched off Display resp setting the frequency frequency in 1 m Hz or FPM Change the frequency by pressing the buttons PLUS E MINUS D DIV F and or MUL G Description Sel...

Page 8: ...This function allows the flash duration to be adjusted which influences the brightness and focus of the object being viewed In the standard mode this setting can only be made in relative form degrees...

Page 9: ...or all other settings Note The stroboscope function is disabled in the TACHO mode LEDs off In the TACHO mode the backlight in the display changes to orange Momentarily press the button Laser C to acti...

Page 10: ...s Menu M B and MINUS D simultaneously No Battery status Battery status LASER EXT LASER EXT Display Adjustable parameters Description Battery fully charged Battery half charged The trigger frequency is...

Page 11: ...tual rotational speed of the fan Images 1 3 5 6 and 8 correspond to the original one which means the rotational speed could be 3 300 1 650 1 100 825 or 550 rpm Which is correct To determine the fan s...

Page 12: ...Notes 12 Operating instructions RT STROBE pocketLED LASER...

Page 13: ...5 4BU UK Tel 44 0 113 287 4411 Fax 44 0 113 287 4422 sales rheintacho co uk www rheintacho com We reserve the right to make technical changes P05391A Status August 2018 RHEINTACHO Vision Systems S A S...

Reviews: