6. Getting started
6.1 Brief description of set-up steps
Please follow the steps below when setting up the device:
1. Place 3 AA size batteries or NiMH rechargeable batteries into
the device.
2. Direct the device at a moving object and switch on. Press
the button “ON / OFF” (A) for at least 1 second.
The device will start to flash straightaway. For this reason,
do not direct it at people or animals.
• The device will flash at the frequency that was set most recently.
The display shows the selected flash frequency in the unit that
was set most recently (1/min, Hz or FPM).
▪ If the flash frequency coincides with the frequency of the motion,
a static image appears.
▪ If necessary, reset to factory setting by pressing and holding the
buttons Menu “M” (B) and “MINUS” (D) simultaneously.
Note
Static images are produced when the flash frequency is identical
to, or a multiple or fraction of the frequency of the motion (see also
section 9 “Determining the actual rotational speed of an object”).
6.2 Additional operating instructions for the version with
trigger connection
Caution
Do not use signals over 999,999 FPM Hz to trigger the device.
Note
The device must be switched manually between external and
internal trigger signal. Thus the 24 V sensor supply is switched on.
Terminal connection assignment trigger jack (Figure 3)
Caution
Please observe the terminal connections shown in the terminal
connection diagram (figure 3).
The trigger input is suitable for NPN signals. A cable with plug,
corresponding to these input jacks, is provided with the device. The
trigger jack is located at the lower part in the center of the device.
Figure 3: Terminal connection assignment
Note
The device must be manually switched between external and
internal trigger signals (see section 7.2.2 “Standard selection” /
How to select an internal / external trigger).
7. Operation
Note
Please note that this device comes in two versions.
Version 1:
Stroboscope pocketLED LASER without trigger
Version 2:
Stroboscope pocketLED LASER with trigger
Both versions are available in standard and pro modes (see
sections 7.2.2 “Standard selection” and 7.2.3 “Pro selection”).
7.1 Button assignment (Figure 1 on page 2)
No. Button Description
(A) ON / OFF
(B) Menu
(C) Laser
(D) MINUS
(E) PLUS
(F) DIV
(G) MUL
Note
The symbol of a parameter that differs from the factory settings will
flash during operation.
6
Operating instructions
RT STROBE pocketLED LASER
- Switch on the device by pressing the button
for at least 1 second.
- Press this button to switch between the
different settings and operation modes
in the sequence of the display indicator
(see figure 2).
- Press this button to activate the laser.
- The laser is activated and measures the
frequency as long as the button is pressed.
>> In the STROBO mode: The device flashes
upon recognition of the reflective tape.
>> The minimum, maximum and average
values are determined (min, max,
average).
>> If the measured value remains within a
tolerance of ± 5 % for 2 seconds,
this value is taken over as a new flash
frequency after releasing the button.
- Momentarily press the button to activate.
The laser remains activated until the button is
pressed again.
- This button can also be used to confirm
selected settings.
- Decreases the currently selected value.
>> Accelerates when this button is pressed.
- Switch between the various settings.
- Increases the currently selected value.
>> Accelerates when this button is pressed.
- Switch between the various settings.
- Halves the currently selected value.
>> Accelerates when this button is pressed.
- Doubles the currently selected value.