The 

Rheem IQ

®

 Link DPi1

 controller is suitable for connection where a separate pump

is installed on a heating circuit in combination with a Rheem Thermal heat pump.

 

OPERATION

The DPi1 controller is designed to switch a 240V pump, rated to 9.98 Amps, 2395 watts

controlled from the ‘HEATER INTERLOCK’ output of a Rheem Thermal heat pump.

 

DEMAND HEAT

Your Rheem Thermal heat pump includes Rheem IQ

®

 which provides a range of

advanced control functions to aid operation and service. This includes a ‘CYCLE TO TEST 

TEMPERATURE’ function that will assist in maintaining the temperature of the pool or spa

by communicating to the DPi1. The DPi1 will start the circulator pump when heating is

called for by the Rheem IQ

®

 controller, which monitors the pool or spa temperature.

PROGRAMMING DEMAND HEAT

To program and switch on the demand heat function in the Rheem Thermal heat pump

controller, refer to the back page of these instructions.

RHEEM THERMAL

RHEEM IQ® LINK 

DPi1

DIGITAL PUMP

INTERFACE 

Summary of Contents for THERMAL IQ LINK DPi1

Page 1: ...p includes Rheem IQ which provides a range of advanced control functions to aid operation and service This includes a CYCLE TO TEST TEMPERATURE function that will assist in maintaining the temperature of the pool or spa by communicating to the DPi1 The DPi1 will start the circulator pump when heating is called for by the Rheem IQ controller which monitors the pool or spa temperature PROGRAMMING DE...

Page 2: ...place Adjusting screws on the back of unit to ensure snug fit To remove unit lift and gently pull away from structure Rheem Thermal Heat Pump Flow Flow Heater Interlock Pool Spa PLUG INTO 240V GPO RHEEM IQ LINK DPi1 DIGITAL PUMP INTERFACE P N 26843 WARRANTY This range of product is covered by a limited 2 year warranty against component failure or faulty workmanship from the date of installation A ...

Page 3: ... the Rheem IQ controller screen on your heat pump as follows 1 Whilst in the home screen press and release The screen will change to the Main menu 2 Press and release or until A On Off Unit is selected 3 Press and release The screen will change to show ON or OFF 4 Press and release or The screen will change to show Type of circulating pump control and the current setting 5 Press and release The fi...

Page 4: ...he home menu 24 Press and hold or for 2 seconds to clear all active alarms The Rheem Thermal heat pump is now programmed and ready to use with the Rheem IQ Link DPi Digital Pump Interface Controller The Cycle to Test Temperature function should be set at the time of installation by the installer and does not normally require changing Controller set up is completed Australia n Standard AS NZS 2712 ...

Page 5: ...SW 2212 PO Box 146 Moorebank NSW 1875 Australia Sales 1300 132 950 Service 02 9684 3684 Intl 61 2 9684 3684 Fax 02 9684 3698 Email sales rheemthermal com au Web www rheemthermal com au ABN 21 098 823 511 Australia n Standard AS NZS 2712 Lic SMK 0757 Lic SMK 1048 Lic SMKP 21548 SAI Global AS 3498 Lic WMKA 00153 Lic WMKA 00177 Lic WMKA 00299 Lic WMKA 00500 Lic WMKA 21434 Lic WMKA 21549 Lic WMKA 2176...