SVC 810 Tankless Troubleshooting Manual
53
Error Code 16
Explanation: Outlet water temperature is to hot. The outlet water temperature is above set point
on the remote control. The unit cannot resolve the issue with the cold-water by-pass function.
Error Code 21 (Indoor Models Only)
Explanation: Air intake filter switch does not work. The air intake filter switch ensures the front
cover is attached and the inlet filter screen is in place and clean. Air intake switch and Error
Code 21 has been removed from second generation 4.2, 5.3 and all Direct Vent (DV) models. At
a minimum check the following:
1.
Make sure air filter door is properly seated and clean.
2.
Make sure front panel is properly installed with all four retaining screws.
3.
Press the air intake switch when operating the unit without the front cover installed.
Yes
The water heater appears to be normal. Attempt
to operate again. Check the water flow servo –
especially the cold water bypass solenoid for
operation. Check for blockage in the cold water
bypass piping.
Does the
maintenance
information
indicate the hot
water outlet temp?
No
Is the resistance
to the hot outlet
thermistor OK?
Measure the resistance of
connector R between Black#3
and Red#4 wires: 4k - 10 k ohms
Display maintenance information line [5y] Hot Water
Outlet Thermistor temperature.
No
Replace Hot Water
Outlet Thermistor.
Replace Printed Circuit
Board.
Yes
Replace the Printed Circuit Board
Is the Air Filter
switch OK?
Yes
No
Replace Air Filter Switch Assy
Press filter switch down. Measure the voltage and resistance of
connector O between both white wires:
Voltage = less than 1 VDC
Resistance = 1 ohm
Summary of Contents for SVC 810
Page 21: ...SVC 810 Tankless Troubleshooting Manual 20 Fan Speed Chart ...
Page 22: ...SVC 810 Tankless Troubleshooting Manual 21 RTG2 42 Wiring Diagram ...
Page 23: ...SVC 810 Tankless Troubleshooting Manual 22 Printed Circuit Board ...
Page 24: ...SVC 810 Tankless Troubleshooting Manual 23 RTG 53 Wiring Diagram RTG 53 ...
Page 25: ...SVC 810 Tankless Troubleshooting Manual 24 Printed Circuit Board RTG 53 ...
Page 26: ...SVC 810 Tankless Troubleshooting Manual 25 RTG 66 Wiring Diagram ...
Page 36: ...SVC 810 Tankless Troubleshooting Manual 35 Printed Circuit Board RTG 74 ...