SVC 810 Tankless Troubleshooting Manual
10
Heat Exchanger Thermistor
The Heat Exchanger Thermistor monitors the temperature of the water
inside the heat exchanger. It will activate to Error Code 15 if the water
temperature exceeds 207º F for more than 15 seconds; or 230º F for more
than 1 second. It will also show an Error Code 32 if the thermistor is
disconnected from the circuit board.
Maintenance Panel Display
The Rheem Tankless has a Maintenance Display chart on the remote
control panel. To access the Maintenance Display, turn the unit OFF.
Then hold down the UP and DOWN arrow keys at the same time for a
few seconds. You will hear an audible beep and see the display go to
0E. By pressing the UP and DOWN arrow keys on the remote display,
you can access a variety of information about the machine. For Example
a code at 3E (recent faults) may display as 21 (Error Code 21).
Shortcut: Lift dip switch #1 to the up position to go immediately into maintenance mode.
First Digit – Use DOWN (
▼
)arrow key on Remote Control
0* 1* 2* 3* 4* 5* 6* 7* 8* 9*
*E
Null
Fault Codes of the most recent 8 faults
Null
*F
Null
Sequence Number of the most recent 8 faults
Null
*C
Total combustion times until recent error fault (** x 10000times)
Null
*D
Total combustion times until recent error fault (** x 100 times)
Null
*H
Total combustion period until recent error fault (** x 1000 hours)
Null
*J
Total combustion period until recent error fault (** x 10 hours)
Null
*Y
Fla
m
e Rod
Status
GP
M Flow R
a
te
(*.* gpm
)
Amb
ient Air
Thermistor
Temper
ature
Co
ld
Wa
ter
Inlet
Thermistor
Temper
ature
Heat
E
x
ch
an
g
er
Thermistor
Temper
ature
Ho
t Wa
ter
Outlet
Thermistor
Temper
ature
F
a
n
S
p
ee
d x 1
0
0
RPM
Power for
P.G.F.R. va
lve
Null
Null
Seco
nd
Di
git –
Use
UP
(
►
) a
rr
ow
ke
y
on
R
emot
e
C
ont
ro
l
*A
Thermo
Electromot
iv
e Fo
rce
C
ont
ro
l
Line
Vo
lta
ge
Fan
Detectiv
e
Value
Fan Motor
Cu
rren
t
Nu
ll
Nu
ll
Nu
ll
Nu
ll
Nu
ll
Sequence
Nu
mbe
r
You can turn the unit on while in Maintenance Mode by quickly pressing the ON/OFF button
one time. The temperature will default to 120 degrees and will not display because you are still
in Maintenance Mode. If you demand hot water, the unit will fire off and you will be able to read
the “Y” line in real time. That means you will see the actual flow rate in gallons per minute, the
cold-water inlet temperature, the hot water outlet temperature, heat exchanger temperature, and
flame rod status.
Summary of Contents for SVC 810
Page 21: ...SVC 810 Tankless Troubleshooting Manual 20 Fan Speed Chart ...
Page 22: ...SVC 810 Tankless Troubleshooting Manual 21 RTG2 42 Wiring Diagram ...
Page 23: ...SVC 810 Tankless Troubleshooting Manual 22 Printed Circuit Board ...
Page 24: ...SVC 810 Tankless Troubleshooting Manual 23 RTG 53 Wiring Diagram RTG 53 ...
Page 25: ...SVC 810 Tankless Troubleshooting Manual 24 Printed Circuit Board RTG 53 ...
Page 26: ...SVC 810 Tankless Troubleshooting Manual 25 RTG 66 Wiring Diagram ...
Page 36: ...SVC 810 Tankless Troubleshooting Manual 35 Printed Circuit Board RTG 74 ...