SVC 810 Tankless Troubleshooting Manual
45
Warning Code 10
Explanation: This is a warning code. Fan Motor is not creating enough ventilation. The venting
system passed pre-purge, but has failed during normal operation. At a minimum check the
following:
1.
Check for blockage of heat exchanger fins.
2.
Check heat exchanger flapper valve at vent connection of water heater moves freely.
3.
Clean air intake filter.
4.
Remove all obstructions. Check the vent termination on the outside of the building and
the flapper valve at the top of the heat exchanger.
This warning code is followed by failure Error Code 99.
Error Code 11
Explanation: No ignition. This error code can be cause one three different scenarios. Please
match the scenario to the fault condition before you troubleshoot. At a minimum check the
following in all cases:
7.
Ensure you have gas to the appliance.
8.
Bleed all air from gas lines.
9.
Ensure appliance is properly grounded.
10.
Ensure gas line, meter, and regulator are sized properly.
11.
Ensure gas type and gas pressure to the machine is correct.
12.
Flex lines with a full 3/4 inch inside diameter may also restrict fuel flow enough to give
you error code 11. We do not condone the use of flex line gas piping with tankless.
Scenario 1 – Error Code 11; fan is operating; igniter does not spark.
Yes
Replace Igniter Assembly
Replace Printed Circuit Board
Does the igniter
have voltage?
No
Yes
Is the igniter
electrode clean?
Is the electrode
damaged? Is
wiring intact?
No
Clean/replace igniter electrode.
Verify good ground.
Measure the voltage of connector H between both gray wires:
108 to 132 VAC.
You will need to cycle the unit to initiate an ignition attempt to
conduct this test.
Remove the burner cover plate to inspect the igniter.
Summary of Contents for SVC 810
Page 21: ...SVC 810 Tankless Troubleshooting Manual 20 Fan Speed Chart ...
Page 22: ...SVC 810 Tankless Troubleshooting Manual 21 RTG2 42 Wiring Diagram ...
Page 23: ...SVC 810 Tankless Troubleshooting Manual 22 Printed Circuit Board ...
Page 24: ...SVC 810 Tankless Troubleshooting Manual 23 RTG 53 Wiring Diagram RTG 53 ...
Page 25: ...SVC 810 Tankless Troubleshooting Manual 24 Printed Circuit Board RTG 53 ...
Page 26: ...SVC 810 Tankless Troubleshooting Manual 25 RTG 66 Wiring Diagram ...
Page 36: ...SVC 810 Tankless Troubleshooting Manual 35 Printed Circuit Board RTG 74 ...