background image

A. Water Heater Location
 

 

 

Close to area of heated water demand.

      

 

❑ 

Indoors and protected from freezing temperatures.

      

 

❑ 

Area free of flammable vapors.

   

   

❑ 

Provisions made to protect area from water damage.

 

❑ 

Sufficient room to service water heater.

 

B.  Water Supply

 

❑ 

Water heater completely filled with water.

 

❑ 

Water heater and piping air vented

 

❑ 

Water connections tight and free of leaks

C.   Relief Valve

 

❑ 

Temperature and Pressure Relief Valve properly installed 

    and discharge line run to open drain

 

❑ 

Discharge line protected from freezing.

D.  Wiring

 

❑ 

Power supply voltage agrees with water heater rating plate.

  ❑ 

Branch circuit wire and fusing or circuit breaker of proper size.

  ❑

  Electrical connections tight and unit properly grounded.

B.  Non-metallic sheathed cable or metallic conduit or metallic sheathed 

cable not approved for use as a ground conductor shall include a 

separate conductor for grounding. It should be attached to the ground 

terminals of the water heater and the wiring junction bracket. (Refer 

to Fig. 3)

The manufacturer’s warranty does not cover any damage or defect caused 
by installation, attachment or use of any type of energy saving or other 
unapproved devices (other than those authorized by the manufacturer) into, 
onto or in conjunction with the water heater. The use of unauthorized en-
ergy saving devices may shorten the life of the water heater and may en-
danger life and property. The manufacturer disclaims any responsibility for 
such loss or injury resulting from the use of such unauthorized devices. 

If local codes require external application of insulation blanket kits the 
manufacturer’s instructions included with the kit must be carefully fol-
lowed.

Application of any external insulation to this water heater will require care-
ful attention to the following:

  •  Do not cover the temperature and pressure relief valve.
  •  Do not cover jacket access panels to thermostats and heating 

elements.

  •  Do not cover electrical junction box of water heater.
  •  Do not cover operating or warning labels attached to the water 

heater nor attempt to relocate them on exterior of insulation blan-
ket.

5

CAUTION

!

WARNING

!

Installation

Installation Check List

  Model No. 

Serial No. 

Date of Installation 

Installed By:

Notes

Summary of Contents for Single and Double Element Models

Page 1: ...e for Future Reference Recognize this symbol as an Indication of Important Safety Information The purpose of this manual is twofold one for the installing contrac tor to provide requirements and recommendations for the proper installation and adjustment of the water heater and two for the owner operator to explain the features operation safety precau tions maintenance and trouble shooting of the w...

Page 2: ...was shipped from the factory The illustration above shows the temperature adjustment dial used for setting the water temperature Refer to Operation section of this manual for detailed instructions in how to adjust the thermostat s There is a Hot Water SCALD Potential if the thermostat is set too high Mixing valves for reducing point of use water temperature by mixing hot and cold water in branch w...

Page 3: ...alve causing it to operate during each heating cycle Thermal expansion and the result ing rapid and repeated expansion and contraction of components in the water heater and piping system can cause premature failure of the relief valve and possibly the heater itself Replacing the relief valve will not correct the problem The suggested method of controlling thermal expansion is to install an expansi...

Page 4: ... approved for use as a grounding conductor and installed with fittings approved for the pur pose Installation Figure 2 Typical Installation Pictured from rear of heater with Top Panel and Insulation Pad removed Figure 3 Location of water connections on water heater tank Pictured with top insulation pad removed WARNING Hot Water Outlet to Fixtures To Electrical Distribution Panel Use only Copper Co...

Page 5: ...anufacturer s warranty does not cover any damage or defect caused by installation attachment or use of any type of energy saving or other unapproved devices other than those authorized by the manufacturer into onto or in conjunction with the water heater The use of unauthorized en ergy saving devices may shorten the life of the water heater and may en danger life and property The manufacturer disc...

Page 6: ...r is OFF before removing front center panel or top panel FOR ANY REASON If adjustment is necessary turn off power to water heater remove front center panel and insulation exposing thermostats The thermostat protective covers should not be removed Set thermostats dial pointers with a small screwdriver to desired temperature Refer to Fig 4 Replace insulation and front center panel Turn on power to w...

Page 7: ...e from your plumber or local plumbing supply store 2 ANODE ROD INSPECTION The anode rod should be removed from the water heater s tank annually for inspection and replaced when more than 6 of core wire is exposed at either end of the rod Refer to Fig 2 or 3 for anode rod location Make certain cold water supply is turned off before removing anode rod Operation Maintenance DANGER button Replace insu...

Page 8: ...allonTableTop Models Single and Double Element Instructions for placing a Parts Orders Address parts orders to the distributor or store from where the heater was purchased All parts orders should include 1 Model number and Serial number of heater from rating plate 2 Specify voltage and wattage as marked on rating plate 3 Part Description as noted at right and number of parts desired These parts ar...

Page 9: ...cription Req d 1 SplashTop 1 2 Front Center Panel 1 3 UpperThermostat on double element models only 1 4 UpperThermostat Protective Cover on double element models only 1 5 Thermostat Bracket As Req d 6 Heating Element Gasket As Req d 7 Heating Element As Req d 8 LowerThermostat Protective Cover 1 9 LowerThermostat 1 10 DrainValve 1 11 DipTube 1 12 DipTube Gasket 1 13 Anode 1 14 ReliefValve 1 Owners...

Page 10: ...ittings when in operation and does not indicate a need for service For your safety DO NOT attempt repair of Electrical Wiring Thermostat s Heating Elements or other Operating Controls Refer repairs to qualified service personnel CAUTION 1 Should you have any questions about your new water heater or if it requires adjustment repair or routine maintenance it is suggested that you first contact your ...

Page 11: ...heaters up to 52 gallon capacity a brochure with generic earthquake bracing instructions can be obtained from OFFICE OFTHE STATE ARCHITECT 1102 Q Street Suite 5100 Sacramento CA 95814 Telephone 916 445 8100 or ask a water heater dealer However applicable Local Codes shall govern installations For residential water heat ers of capacity greater than 52 gallons consult the local building jurisdiction...

Page 12: ...TRIBUTION PANEL G G G BRANCH CIRCUIT TO ELECTRICAL DISTRIBUTION PANEL UPPER THERMOSTAT HIGH TEMP LIMIT ECO 2 UPPER HEATING ELEMENT BLUE L1 JUNCTION BOX 4 L2 1 3 RED 10 GA BLACK LOWER HEATING ELEMENT LOWER THERMOSTAT HIGH TEMP LIMIT ECO 1 2 4 1 3 1 2 RED 2 BLACK 10 GA YELLOW BLACK 10 GA RED 10 GA G 2 UPPER THERMOSTAT HIGH TEMP LIMIT ECO UPPER HEATING ELEMENT BLUE L1 BRANCH CIRCUIT TO ELECTRICAL DIS...

Reviews: