Contents of function setting
Each function setting listed in this section is adjustable in accordance with the installation environ-
ment.
NOTE:
Setting will not be changed if invalid numbers or setting values are selected.
Function setting list
Function no.
Functions
1)
11
Filter sign
2)
30/31
Room temperature control for indoor unit sensor
3)
40
Auto restart
4)
42
Room temperature sensor switching
5)
44
Remote controller custom code
6)
46
External input control
7)
48
Room temperature sensor switching (Aux.)
8)
92/93
Room temperature control for wired remote controller sensor
9)
94
Fixed operation mode switching
10)
95
Heat insulation condition (building insulation)
1) Filter sign
Select appropriate intervals for displaying the filter sign on the indoor unit according to the esti-
mated amount of dust in the air of the room.
If the indication is not required, select "No indication" (03).
Function number
Setting value
Setting description
Factory setting
11
00
Standard (400 hours)
01
Long interval (1,000 hours)
02
Short interval (200 hours)
03
No indication
♦
DESIGN & TECHNICAL MANUAL
- 24 -
WALL MOUNTED
RIWH18-24AVFJ
Summary of Contents for RIWH18AVFJ
Page 5: ...Part 1 INDOOR UNIT WALL MOUNTED TYPE RIWH18AVFJ RIWH24AVFJ...
Page 9: ...3 Wiring diagrams 3 1 Models RIWH18AVFJ and RIWH24AVFJ 5 WALL MOUNTED RIWH18 24AVFJ...
Page 35: ...Part 2 OUTDOOR UNIT SINGLE TYPE ROSH18AXFWJ ROSH24AXFWJ...
Page 42: ...5 Wiring diagrams 5 1 Model ROSH18AXFWJ 38 OUTDOOR UNIT ROSH18 24AXFWJ...
Page 43: ...5 2 Model ROSH24AXFWJ 39 OUTDOOR UNIT ROSH18 24AXFWJ...