- (02 - 15) -
SAFETY DEVICES
10.
Protection form
Model
ROSH09AFCJ
ROSH12AFCJ
ROSH18AFCJ
Circuit protection
Current fuse
(Near the terminal)
250V 20A
250V 25A
250V 5A
Current fuse
(Main printed circuit board)
250V 15A
250V 10A
250V 3.15A
Fan motor protection
Thermal protection
program
OFF : 212±27 °F (100±15 °C)
ON : 203±18 °F (95±10 °C)
Compressor protection
Thermal protection
program
(Discharge temp.)
OFF : 230 °F (110 °C)
ON : After 7 minutes