- (02 - 06) -
CAPACITY COMPENSATION RATE FOR PIPE LENGTH
5.
AND HEIGHT DIFFERENCE
MODEL :
ROSH09AFCJ, ROSH12AFCJ
HEATING
Pipe length
5m
7.5m
10m
15m
20m
17ft.
25ft.
33ft.
50ft.
67ft.
Height
difference H
1
Indoor unit is
higher than
outdoor unit.
15m
50ft.
-
-
-
0.933
0.925
10m
33ft.
-
-
0.981
0.933
0.925
7.5m
25ft.
-
1.000
0.981
0.933
0.925
5m
17ft.
1.017
1.000
0.981
0.933
0.925
0m
0ft.
1.017
1.000
0.981
0.933
0.925
2
Indoor unit is
lower than
outdoor unit
-5m
-17ft.
1.012
0.995
0.976
0.928
0.920
-7.5m
-25ft.
-
0.993
0.974
0.926
0.918
-10m
-33ft.
-
-
0.971
0.923
0.916
-15m
-50ft.
-
-
-
0.914
0.906
COOLING
Pipe length
5m
7.5m
10m
15m
20m
17ft.
25ft.
33ft.
50ft.
67ft.
Height
difference H
1
Indoor unit is
higher than
outdoor unit.
15m
50ft.
-
-
-
0.877
0.874
10m
33ft.
-
-
0.956
0.891
0.888
7.5m
25ft.
-
0.988
0.960
0.895
0.892
5m
17ft.
1.017
0.992
0.964
0.899
0.895
0m
0ft.
1.025
1.000
0.971
0.906
0.902
2
Indoor unit is
lower than
outdoor unit
-5m
-17ft.
1.025
1.000
0.971
0.906
0.902
-7.5m
-25ft.
-
1.000
0.971
0.906
0.902
-10m
-33ft.
-
-
0.971
0.906
0.902
-15m
-50ft.
-
-
-
0.906
0.902
Height difference H
1 Indoor unit is higher than outdoor unit.
2 Indoor unit is lower than outdoor unit.
Indoor unit
Indoor unit
Connection pipe
Outdoor unit
Outdoor unit
Connection pipe
H
H
Summary of Contents for RIDH09AVFJ
Page 2: ...1 INDOOR UNIT DUCT TYPE RIDH09AVFJ RIDH12AVFJ RIDH18AVFJ...
Page 12: ...01 09 5 WIRING DIAGRAMS MODELS RIDH09AVFJ RIDH12AVFJ RIDH18AVFJ...
Page 48: ...2 OUTDOOR UNIT SINGLE TYPE ROSH09AFCJ ROSH12AFCJ ROSH18AFCJ...
Page 53: ...02 04 4 WIRING DIAGRAMS MODEL ROSH09AFCJ ROSH12AFCJ...
Page 54: ...02 05 MODEL R O S H 1 8 A F C J...
Page 62: ...02 13 SOUND LEVEL CHECK POINT 8 2 39 3 8in 1m Airflow Microphone Microphone...