- (01 - 37) -
FUNCTION DETAILS
Functions
1) Filter sign
2) Static pressure
3) Room temperature control for indoor unit sensor
4) Auto restart
5) Room temperature sensor switching
6) Remote controller custom code
7) External input control
8) Room temperature sensor switching (Aux.)
9) Room temperature control for wired remote controller sensor
10) Heat Insulation condition (building insulation)
1) Filter sign
Select appropriate intervals for displaying the
fi
lter sign on the indoor unit according to the estimated
amount of dust in the air of the room.
If the indication is not required, select "No indication" (03).
(
... Factory setting
Function number
Setting value
Setting description
11
00
Standard (400 hours)
01
Long interval (1000 hours)
02
Short interval (200 hours)
03
No indication
2) Static pressure
Select the appropriate static pressure according to the installation conditions.
(
... Factory setting)
Function number
Setting value
Setting description
26
00
0 in.WG (0 Pa)
01
0.04 in.WG (10 Pa)
02
0.08 in.WG (20 Pa)
03
0.12 in.WG (30 Pa)
04
0.16 in.WG (40 Pa)
05
0.20 in.WG (50 Pa)
06
0.24 in.WG (60 Pa)
07
0.28 in.WG (70 Pa)
08
0.32 in.WG (80 Pa)
09
0.36 in.WG (90 Pa)
31
0.10 in.WG (25 Pa) [Standard]
Summary of Contents for RIDH09AVFJ
Page 2: ...1 INDOOR UNIT DUCT TYPE RIDH09AVFJ RIDH12AVFJ RIDH18AVFJ...
Page 12: ...01 09 5 WIRING DIAGRAMS MODELS RIDH09AVFJ RIDH12AVFJ RIDH18AVFJ...
Page 48: ...2 OUTDOOR UNIT SINGLE TYPE ROSH09AFCJ ROSH12AFCJ ROSH18AFCJ...
Page 53: ...02 04 4 WIRING DIAGRAMS MODEL ROSH09AFCJ ROSH12AFCJ...
Page 54: ...02 05 MODEL R O S H 1 8 A F C J...
Page 62: ...02 13 SOUND LEVEL CHECK POINT 8 2 39 3 8in 1m Airflow Microphone Microphone...