background image

Page 16 

EXCLUSIVE WARRANTY – LIMITATION OF LIABILITY

This Limited Warranty is the only Warranty given by the manufacturer, the Rheem Water Heater 

Operation of Rheem Manufacturing Company, for this unit . No one is authorized to make any other 

warranties on behalf of the manufacturer . 

ANY IMPLIED WARRANTIES, INCLUDING 

MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXTEND 

BEYOND THE  APPLICABLE WARRANTY PERIODS SPECIFIED PREVIOUSLY. THE 

 MANUFACTURER’S SOLE LIABILITY, WITH RESPECT TO ANY DEFECT, SHALL BE AS SET 

FORTH IN THIS LIMITED WARRANTY AND ANY CLAIMS FOR INCIDENTAL OR 

 CONSEQUENTIAL DAMAGES (INCLUDING DAMAGE FROM WATER LEAKAGE) ARE 

EXCLUDED. 

Some states do not allow limitations on how long an implied warranty lasts, or for the 

exclusion of incidental or consequential damages, so the above limitations or exclusions may not 

apply to you .

This Limited Warranty gives you specific legal rights, and you may also have other rights, which vary 

from state to state .

We suggest you immediately complete the information below and retain this Certificate of Limited 

Warranty in the event warranty service is needed . Reasonable proof of the date of original 

 installation or date of original purchase of your  water heater (whichever came first) may be required 

to establish its “in-warranty” status . Otherwise, the Effective Date of the Limited Warranty will be the 

date of manufacture plus ninety (90) days .

DO NOT RETURN THIS DOCUMENT TO RHEEM. 

KEEP IT WITH YOUR  WATER HEATER OR BUSINESS RECORDS.

Name of Owner/Business Location 
where this  Water Heater is Installed: _______________________________________________________

 Water Heater Installation Location Address:  _________________________________________________

_____________________________________________________________________________________

Date  Water Heater was Installed: __________________________________________________________

Name of Rheem Retailer: ________________________________________________________________

Address of Rheem Retailer:  ______________________________________________________________

_____________________________________________________________________________________

Telephone Number of Rheem Retailer: ______________________________________________________

Complete Model Number of  Water Heater: _____________________________________________________

Summary of Contents for Indirect Water Heater

Page 1: ...g the indirect water heater into service This unit must be installed by licensed or authorized installers or technical personnel that service water heating equipment The indirect water heater must be...

Page 2: ...Section I Specifications 3 Section II General Informations 5 Section III Pre Installation 7 Section IV Installation 9 Section V Maintenance 12 Section VI Troubleshooting 13 Section VII Parts List 14...

Page 3: ...erature setting for normal residential use is 120 F Rheem recommends a tempering valve or anti scald valve be installed and used according to the manufacturer s directions to prevent scalding STID30 2...

Page 4: ...000 202 104 000 214 111 000 STID80 188 76 000 212 91 000 224 98 000 221 97 000 233 104 000 245 112 000 257 119 000 STID120 220 76 000 244 91 000 256 98 000 253 97 000 265 104 000 277 112 000 289 119 0...

Page 5: ...ited control for domestic hot water temperature The proper temperature setting for domestic hot water use is 120 F 49 C If hotter water is required a tempering device or anti scald device must be inst...

Page 6: ...ter system When hydrogen is present there will probably be an unusual sound such as air escaping through the pipe as the water begins to flow There should be no smoking or open flame near the faucet a...

Page 7: ...F and 200 F boiler water To determine the appropriate circulator for your system follow these three steps 1 Calculate the pressure drop of all straight pipe and fittings on the supply and return at th...

Page 8: ...imum coil output assume coil output boiler output listed in Tables 2 and 3 is not met the output first hour rating of the indirect water heater will not be met at the selected flow rate To approximate...

Page 9: ...minimized A flow check valve must be installed on the return line All piping to the inlet cold and outlet hot domestic water connections should be new copper with a minimum size of 1 2 ID for models S...

Page 10: ...tion cont CHECK VALVES ZONE CIRCULATORS ISOLATION VALVES ADDITIONAL ZONES INDIRECT CIRCULATOR INDIRECT WATER HEATER TO HEATING ZONE AIR SEPARATOR AIR VENT EXPANSION TANK COLD WATER INLET BOILER CIRCUL...

Page 11: ...m circulator stays off and the boiler must light to reach high limit WIRING NOTES 1 Dashed lines indicate low voltage 24 VAC 2 Use jumper wire between terminals 1 and 3 on R845 relay THERMOSTAT SPECIF...

Page 12: ...nd at least yearly once a time interval for inspection has been developed It is recommended to check the rod s six months after the heater is installed If the anode rod had reduced in size by two thir...

Page 13: ...HFN SRZHU VXSSO 5HSODFH DV QHFHVVDU DXOW WDQN DTXDVWDW 5HSODFH DTXDVWDW RLOHU F FOHV PRUH WKDQ WLPHV SHU GD GXULQJ KRWHVW PRQWKV FHVVLYH GHPDQG 5HGXFH GHPDQG RU FRQVLGHU ODUJHU WDQN DXOW DTXDVWDW 5HSO...

Page 14: ...n VIi parts list No Description Applicable Models 1 Anode All models 2 Anode Outlet STID 30 STID 40 STID 50 3 T P Relief Valve All models 4 Drain Valve All models 5 Aquastat All models Page 14 14 2 1...

Page 15: ...nt component part s to a convenient delivery point selected by Rheem near the place the original water heater or original component part s is located such as a local Rheem water heater retailer You mu...

Page 16: ...rranty in the event warranty service is needed Reasonable proof of the date of original installation or date of original purchase of your water heater whichever came first may be required to establish...

Reviews: