Fault Finding Tests 8 ~ 10
Test 8
Using a multimeter set on the DC voltage
scale, measure between SV1 wiring
terminal (orange wire) and the black earth
wire on the gas valve body. The following
result should be obtained
during the
ignition period
:
1.1 ~ 2.1 VDC.
Test 9
Using a multimeter set on the DC voltage
scale, measure between SV2 wiring
terminal (green wire) and the black earth
wire on the gas valve body. The following
result should be obtained
when the pilot
is alight
:
1.1 ~ 2.1 VDC.
Test 10
Using a multimeter set on the DC voltage
scale, measure between SV3 wiring loom
plug green wire and the black earth wire on
the gas valve body. The following result
should be obtained
when the pilot is
alight
:
1.1 ~ 2.1 VDC.