TM005 Rheem Solar Hiline Service Instructions REV D
D.O.I 20/02/2009
This document is stored and maintained electronically by
Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”.
25
Fault Finding (Chart 8)
Is the noise only evident
when hot water is being
drawn off during periods of
high solar gain?
Check for:
Mineral build up on the heating unit
loop - replace heating unit.
Poor quality water supply i.e. dam
water sludge - flush tank.
Is the noise only evident
when electric heating cycle
is on?
NO
YES
Noise is caused by FLASH STEAM.
Refer to explanation in Hot Water
Physics section.
Is the noise water hammer?
NO
Refer to water hammer explanation in
common complaints section.
YES
YES
Is the noise only evident
when water is flowing
through the water heater?
Check all other appliances that can
generate noise i.e. washing machine,
dishwasher, ball cocks etc.
NO
NO
Is the water pressure above
700kPa?
Check for a faulty stop cock, non-
return valve, ECV or T&PR valve.
Check for restrictions in pipe work,
faulty valves, loose plumbing, other
appliances i.e. washing machine or
dishwasher. Fit PLV if required.
YES
NO
YES
8
Noisy water heater